Download Print this page

Electrolux EDW 1600 Service Manual page 27

Dishwashers with electronic control system
Hide thumbs Also See for EDW 1600:

Advertisement

• iC0 Code - family : Communication Problem
• iC0
code: user interface communication
The error signal is displayed if the communication system does not
recognize any display board.
• iC1
code: MACS bus communication
After three attempts to establish communication, an error is signalled in the
hardware control
• iC2
Code: ADSI communication
The washing programme is suspended but it can be restarted if the alarm
conditions no longer apply
• iC3
Code: Communication between boards
The alarm is signaled if the communication between the power board and
the motor control board does not start.
Acoustic signal and visual alarm, depending on the appliance
customization; the washing program is restarted automatically if the error
conditions no longer apply.
• iD0 Code - family : Tacho Problem
• iD0
code: no signal
The alarm is stored and displayed only in service mode; there is a new
control for each new phase.
If the washing pump is activated but there is no tacho signal for 30 sec
then the motor speed is set to full speed and the heating element is not
activated.
Technical Support – A.R.
Alarm Codes
• iD1
The alarm is stored and displayed only in service mode.
If the washing pump is activated but there is no tacho signal for 5 sec then
the heating element is temporarily deactivated. If after another 30 sec
there is still no signal the appliance displays an error code iD0.
• iE0 – family: flow controller problem
• iE0
The alarm is stored and displayed only in service mode; the flow controller
will try to recover for each new positioning request.
The alarm is signalled if the desired position of the flow controller is not
reached within a certain time:
If the alarm is signalled, then heating element is deactivated as long as the
alarm is active.
iF0 Code - family : water level problem
• iF0
The alarm is stored and displayed only in service mode; the program
continues.
The error situation is recognized when the total filling times exceed the
limits.
The times are accumulated at each subsequent filling and reset by the
cycle package. The subsequent fillings are ignored before the time is reset.
599 79 76 - 54 Rev 2
code: no signal
code: flow control position (spray arm level)
If the flow controller is not moving at all or if the sensor is
o
broken or shorted, the timeout is 12 seconds.
If the flow controller is indeed moving but cannot find the
o
position, the overall timeout is up to about 110 seconds.
Code : overfilling detected
4
Chapter

Advertisement

loading

This manual is also suitable for:

Edw 1850Edw 1950Edw 2200Edw 3510Edw 4010