Electrolux EDW 1600 Service Manual page 20

Dishwashers with electronic control system
Hide thumbs Also See for EDW 1600:

Advertisement

i11
code: during dynamic filling
Acoustic signal and visual alarm, depending on the appliance
customization; the program can be restarted.
The water level defined is not reached within the time limit set.
The time limit set starts when the fill solenoid valve is opened.
The time limit set is reset when the fill solenoid valve is closed.
The water will first be drained before an error is displayed to the user.
Time limit set: Normal 120 sec; Test cycle = 60 sec (times could differ as
they are defined in the washing cycle specifications)
• i20 Code - family : Draining Problem
i20
code : Fails to drain
Acoustic signal and visual alarm, depending on the appliance
customization; the program can be restarted.
The level switch restore point is not reached within the time limit set.
The time limit set starts when the drain pump is activated.
The time limit set is reset when the drain pump stops normally.
Time limit set: Normal 90 sec; Test cycle = 60 sec
• i30 Codes - family : Aqua Control
• i30
code: aqua control error detected
The error is set if there is water detected in the bottom tray, or the drain
pump is disconnected or the winding in the pump is open circuit.
Acoustic signal and visual alarm, depending on the appliance
customization; the program is restarted automatically in this alarm
condition.
If this alarm condition occurs, the drain pump is activated.
Time limit set: 10 sec.
Technical Support – A.R.
Alarm Codes
• i40 Codes - family : Analogue pressure sensor
problem
• i41
code: No pressure sensor signal
The error is set if the sensor signal is lost for more than 2,5s.
Abort program and display error.
• i42
code: Calibration invalid, pressure signal too noisy
The warning is set if the sensor signal is not stable enough for calibration
or if the signal is out of range for an empty sump.
The signal noise level for calibration is defined in MCF.
• i43
code: Pressure sensor signal too high
The error is set if the sensor signal is out of range, signal high for more
than 2,5 s.
The signal range is defined in MCF.
Abort program and display error.
• i44
code: Pressure sensor signal too low
The error is set if the sensor signal is out of range, signal low for more than
2,5 s.
The signal range is defined in MCF.
Abort program and display error.
• i45
code: Calibration invalid, pressure signal too low
The warning is set if the sensor signal is out of range for an empty dw,
signal low.
The signal range for calibration is defined in MCF.
599 79 76 - 54 Rev 2