Alarm Reading and Actuator Test
After accessed Service mode (L1, L2 and L3 blinking):
1. Press button S2 to show the first alarm code.
L1 blinks to indicate the machine is in Alarm Reading.
The first alarm code saved is shown in the display.
Please see later Alarm Codes section.
2. Press button S2 again to show the second alarm code.
3. Press button S2 once more to show the third alarm code.
4. Press button S2 the fourth time to move to Actuator Test. Press
button S2 repeatedly will sequentially turn on one actuator at a
time.
L1 is turned off. L2 blinks to indicate the machine is in
Actuator Test.
The actuator number is shown in the display, see the
following table for details.
Technical Support – A.R.
EDW2200
Number of
S1 Pressed
4
5
6
7
8
9
10
5. Press button S2 when actuator number 10 is activated, the
machine will cycle back to Alarm reading and show the first
alarm code saved.
6. Switching off the appliance will exit Service mode.
LED Test / Delete Alarm Memory
After accessed Service mode (L1, L2 and L3 blinking):
1. Press button S4 to start this function.
All used LEDS and display (show "8:88") blinks 5 second on
1 second off.
If a buzzer is equipped, it beeps for 5 seconds.
The alarm codes saved in memory are erased.
2. Switching off the appliance will exit Service mode.
599 79 76 - 54 Rev 2
Actuator
Number in
Actuator
Display
4
Regeneration Valve
5
Drain Pump
6
Inlet Valve
7
Heater
8
Wash Pump
9
Dispenser
10
Dry Fan
Chapter
Comment
Off when water level
reached
On only if water level
reached