Download Print this page

Electrolux EDW 1600 Service Manual

Hide thumbs Also See for EDW 1600:

Advertisement

Quick Links

SERVICE MANUAL
DISHWASHERS
FOR INTERNAL AND PARTNERS USE ONLY
© ELECTROLUX HOME PRODUCTS
Consumer Service - EMEA
Quality & Continuous Improvement - Technical Support
Dishwashers with electronic control system
SERVICE MODE
• EDW 1600
• EDW 1850
• EDW 1950
• EDW 2200
• EDW 3510
• EDW 4010
EN
Publication number
For internal and partners use only.
599 83 22 - 09
Edition: 08/2019 - Rev. 0

Advertisement

loading

Summary of Contents for Electrolux EDW 1600

  • Page 1 Dishwashers with electronic control system SERVICE MODE • EDW 1600 • EDW 1850 • EDW 1950 • EDW 2200 SERVICE MANUAL • EDW 3510 • EDW 4010 DISHWASHERS FOR INTERNAL AND PARTNERS USE ONLY © ELECTROLUX HOME PRODUCTS Publication number For internal and partners use only.
  • Page 2 Chapter 1 Negative Temperature Coefficient resistor User Interface – Introduction Chapter 2 PB100 New platform for dual BLDC machines (Global hydraulic) EDW 1600 Chapter 3.1 DIVA2 Platform with single BLDC control in separate unit (MCB) EDW 1850 Chapter 3.2 Motor Control Board (DIVA2) EDW 1950 Chapter 3.3...
  • Page 3 User interface – Introduction User Interface – Modes and Function description According to hardware configuration of the dishwasher and marketing requirement, User Mode in individual models can be a subset of above functions. Reset The User Mode functions are not described in this Service Manual “Reset”...
  • Page 4 User interface – Introduction Service Mode – Function description Alarm Reading and Actuator Test After accessed Service mode to get the saved alarms and test actuators. Details of alarm code displaying are in later Alarm Code section. LED Test / Delete Alarm Memory To test the LEDS and erase alarm codes from memory.
  • Page 5 EDW1600 Reset EDW 1600 Press buttons S1+S2 simultaneously for at least 2 seconds to perform Reset function. Styling Overview Access Service Mode The Service Mode can only be accessed after the Reset function Location of LEDs and Push Buttons has been carried out and the appliance is switched off.
  • Page 6 EDW1600 Alarm Reading and Actuator Test Actuator Number of Number in Actuator Comment After accessed Service mode (L1, L2 and L3 blinking): S1 Pressed Display 1. Press button S1 to show the first alarm code. Regeneration Valve L1 blinks to indicate the machine is in Alarm Reading. Drain Pump Off when water level The first alarm code saved is shown in the display.
  • Page 7 EDW1600 Functional Test Cycle Enable/disable Pulse Wash After accessed Service mode (L1, L2 and L3 blinking): After accessed Service mode (L1, L2 and L3 blinking): 1. Press button S3 to start the test cycle. The cycle will not start if 1.
  • Page 8 EDW1850 EDW 1850 Reset Press buttons S3+S4 simultaneously for at least 2 seconds to Styling Overview perform Reset function. Access Service Mode Location of LEDs and Push Buttons The Service Mode can only be accessed after the Reset function has been carried out and the appliance is switched off. Press and hold button S1+S2 simultaneously while turn the appliance on, keep holding the buttons for 4 seconds.
  • Page 9 EDW1850 L1, L2 and L3 blink to indicate that Service mode is accessed. Actuator Number of Alarm Reading and Actuator Test Number in Actuator Comment S1 Pressed Display After accessed Service mode (L1, L2 and L3 blinking): Regeneration Valve 1. Press button S1 to show the first alarm code. Drain Pump L1 blinks to indicate the machine is in Alarm Reading.
  • Page 10 EDW1850 Functional Test Cycle Enable/disable Pulse Wash After accessed Service mode (L1, L2 and L3 blinking): After accessed Service mode (L1, L2 and L3 blinking): 1. Press button S3 to start the test cycle. The cycle will not start if 1.
  • Page 11 EDW1950 Reset EDW 1950 Press buttons S3+S4 simultaneously for at least 2 seconds to perform Reset function. Styling Overview Location of LEDs, Access Service Mode The Service Mode can only be accessed after the Reset function Location of LEDs and Push Buttons has been carried out and the appliance is switched off.
  • Page 12 EDW1950 Alarm Reading and Actuator Test Actuator Number of Number in Actuator Comment After accessed Service mode (L1, L2 and L3 blinking): S1 Pressed Display 1. Press button S1 to show the first alarm code. Regeneration Valve L1 blinks to indicate the machine is in Alarm Reading. Drain Pump Off when water level The first alarm code saved is shown in the display.
  • Page 13 EDW1950 Functional Test Cycle Enable/disable Pulse Wash After accessed Service mode (L1, L2 and L3 blinking): After accessed Service mode (L1, L2 and L3 blinking): 1. Press button S3 to start the test cycle. The cycle will not start if 1.
  • Page 14 EDW2200 EDW 2200 Reset Press the S3 which is dedicated to this function. Styling Overview Access Service Mode The Service Mode can only be accessed after the Reset function has been carried out and the appliance is switched off. Location of LEDs and Push Buttons EDW2200 is a touch key model.
  • Page 15 EDW2200 Alarm Reading and Actuator Test Actuator Number of Number in Actuator Comment After accessed Service mode (L1, L2 and L3 blinking): S1 Pressed Display 1. Press button S2 to show the first alarm code. Regeneration Valve L1 blinks to indicate the machine is in Alarm Reading. Drain Pump Off when water level The first alarm code saved is shown in the display.
  • Page 16 EDW2200 Functional Test Cycle Enable/disable Pulse Wash After accessed Service mode (L1, L2 and L3 blinking): After accessed Service mode (L1, L2 and L3 blinking): 1. Press button S5 to start the test cycle. The cycle will not start if 1.
  • Page 17 EDW3510 Reset EDW 3510 Press the Program Key for at least 2 seconds, and then follow the instructions on the screen to perform Reset function. Styling Overview Access Service Mode EDW3510 is a touch key model. After Reset an off/on, press button S5+S7 simultaneously for at least 4 seconds to access Service Mode.
  • Page 18 EDW4010 Reset EDW 4010 Press the Program Key for at least 2 seconds, and then follow the instructions on the screen to perform Reset function. Styling Overview Access Service Mode EDW4010 is a touch key model. After Reset an off/on, press button S5+S7 simultaneously for at least 4 seconds to access Service Mode.

This manual is also suitable for:

Edw 1850Edw 1950Edw 2200Edw 3510Edw 4010