Download Print this page

Electrolux EDW 1600 Service Manual page 25

Dishwashers with electronic control system
Hide thumbs Also See for EDW 1600:

Advertisement

• i80 Code - family : Auto Door Opener
• i80
code: Auto door opener malfunction
The error is set if the auto door opener sense signal indicates that it has
left the normal position unintentionally while running a cycle, or
If the auto door opener times out without reaching starting position three
times while retracting.
Timeouts are defined in MCF
Abort program and display error
• i81
code: Auto door opener warning
The warning is set if the auto door opener sense signal indicates that it has
left the normal position unintentionally, or
If the auto door opener times out while opening the door and does not
leave the starting position, or
If the auto door opener reverses direction while opening the door and
reach the inside position before expected (door blocked), or
If the auto door opener times out while retracting.
Timeouts are defined in MCF
The warning is not displayed, the cycle continues
• i82
code: Water Reuse valve warning
This warning is set if the Water Reuse valve is detected not opened during
the water tank conditioning, or
If the Water Reuse valve is detected not closed in the beginning of the cold
rinse phase in every Elabel or intensive Care cycle.
The warning is not displayed, the cycle continues.
Technical Support – A.R.
Alarm Codes
• i90 Code - family : Configuration Problem
• i91
code: checksum MCF
No washing program start is possible, can be resolved by turning the
appliance off and back on again.
The display board does not satisfy the identification requests of the main
board.
• i92
code: checksum CCF
The alarm is signalled if the configuration control of the washing cycles
provided erroneous results.
• i93
code: checksum UIDATA
The alarm is signalled if the configuration control of the UI configuration
data provided erroneous results.
• i94
code: UIDATA version mismatch
The alarm is signalled if the UIDATA provided in configuration file
mismatches the attached UI board.
• i95
code: UIDATA checksum mismatch
The alarm is signalled if the UIDATA checksum type provided in
configuration file mismatches with the attached UI board.
599 79 76 - 54 Rev 2
4
Chapter

Advertisement

loading

This manual is also suitable for:

Edw 1850Edw 1950Edw 2200Edw 3510Edw 4010