Download Print this page

Electrolux EDW 1600 Service Manual page 23

Dishwashers with electronic control system
Hide thumbs Also See for EDW 1600:

Advertisement

• i60 Code - family : Heating Element Problem
This family has different meaning depending on PB and PB firmware
releases.
Past production specific
This range includes the following PBs and PB firmware releases:
Diva & Diva2
-
PB150 with P150R100
-
PB200
-
PB300
-
• i60
code: heating
The alarm is stored and displayed only in service mode; the washing
programme continues without the activation of the heating element.
During the heating phases, the rise in temperature is monitored with an
update every 3 min.
Within these 3 minutes, the temperature must rise by at least 1 °C.
• i61
code: heating over temperature
If water temperature is detected higher than 78° C, cycle is stopped.
(rem.: origin of this alarm is problem on visi plastic doors)
• i62
code: relay broken
Alarm is stored and displayed only in service mode; the washing
programme continues without the activation of the heating element.
One or both relays are broken and power board needs to be replaced.
Technical Support – A.R.
Alarm Codes
Current production specific
This range includes the following PBs and PB firmware releases:
PB100
-
PB101
-
PB150 with P150R110 or later
-
A heating alarm is NOT always caused by failure of heater. Service
technicians should following the following sequence to avoid unnecessarily
heater exchange.
Suggestion of general fault diagnosis sequence:
1) Inspect for loose connectors or damage of isolation harness and
2) Check the heater element by unplugging heater connector on PB
3) Check current leakage by plugging in heater connector on PB and
4) Check the relays on the power board by measuring resistance
5) Erase alarms using LEDTest, run LineTest. If the same alarm
i63
The alarm is stored and displayed only in service mode; the washing
program continues running
The causes in the order of probability:
599 79 76 - 54 Rev 2
connector on PB and heater for loose connectors or damage of
isolation.
and measuring heater resistance to be valid. Exchange heater only
if not.
measuring resistance between one heater phase and protective
earth to be > 500kOhm. Exchange heater only if not.
between one heater phase and the two mains power phases to be
>10kOhm. If not broken relay on power board, replace heater.
appear again, exchange power board.
code: heating system error 1
1) Broken heater
2) Damaged harness or connectors
4
Chapter

Advertisement

loading

This manual is also suitable for:

Edw 1850Edw 1950Edw 2200Edw 3510Edw 4010