Electrolux EDW 1600 Service Manual page 21

Dishwashers with electronic control system
Hide thumbs Also See for EDW 1600:

Advertisement

• i46
code: Calibration invalid, pressure signal too high
The warning is set if the sensor signal is out of range for an empty dw,
signal high.
The signal range for calibration is defined in MCF.
• i50 Code - family : Washing Motor Problem
• i51
code: Asynchronous motor problem
Acoustic signal and visual alarm, depending on the appliance
customisation; the programme is suspended.
The washing pump runs without being activated by the software, the cause
is a short-circuit.
The heating element is not activated.
If the alarm occurs, the fill solenoid valve is activated up to the level
pressure switch tripping point, then the cycle is suspended.
Time limit set: 8 sec.
• i52
code: WP BLDC motor – abnormal high current detected
Hardware supervising – will be set when abnormal high current of about
1.3 amps are detected.
• i53
code: WP BLDC motor – over current
Alarm will be set when the current is detected higher than the max allowed
current of 1.0 A
• i54
code: WP will not follow / rotor is locked
Alarm will be set when the motor locked condition is detected during start
of motor and also during the running motor; reasons can be dirt, too high
load, mechanical problems on impeller.
Technical Support – A.R.
Alarm Codes
• i55
code: DCLink undervoltage
Alarm is set when the Vbat voltage on motorcontrolboard will be detected
lower than 225 VDC and will be cleared if voltage is greater than 260 V DC
• i56
code: DCLink overvoltage
Alarm is set when the DCLink voltage on power controlboard is greater
than 392 VDC and will be cleared when dropping under 390 VDC.
i57
code: MCB Vbat voltage plausability / ADC Fault
This code has different meaning depending on platform.
Alarm will be set if Vbat is detected higher than 440V or lower than 215V.
rem.: with Vbat voltage the calculation of the motor resistance is
executed.
Alarm will be set if the difference between current samples are less than
0.03363 [A] for 0.5 s.
• i58
code: WP motor plug connection
Alarm will be set if motor connection is detected wrong based on motor
currents measurements.
If currents are inside the thresholds (+/- 21 mA); debounce is set to 1.5
seconds.
This code is also possible if a phase is detached or if a winding inside the
motor is broken.
599 79 76 - 54 Rev 2
DIVA 2 MCB Vbat voltage plausability
PB100 Drain pump ADC fault
4
Chapter

Advertisement

loading

This manual is also suitable for:

Edw 1850Edw 1950Edw 2200Edw 3510Edw 4010