Removing a management module

Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the
following label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
Complete the following steps to remove a management module.
Note:
v These instructions assume the BladeCenter unit is connected to power.
v If you are removing the only management module in the BladeCenter
unit, you might prefer to stop all management-module local and
remote sessions before proceeding, to avoid unexpected termination of
sessions.
v If you are replacing the only management module in the BladeCenter
unit, and the management module is functional, you might want to
save the configuration file to another medium before you proceed
(under the MM Control section in the navigation pane, click
Configuration File and follow the instructions under Save MM
Configuration); you will be able to restore the saved configuration file
to the replacement management module. See "Restoring a saved
configuration file" on page 32 for more information about applying a
saved configuration file.
v If you have just installed a second management module in the
BladeCenter unit, do not remove the first (primary) management
module for up to 10 minutes; the second (secondary) management
14