Page 1
Montaggio e installazione Rack / Rack assembly and installation MANUALE D’USO USER MANUAL NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! humiFog +0300110IE Up to date version available on www.carel.com...
Page 3
All other The liability of CAREL in relation to its products is specifi ed in the CAREL uses and modifi cations made to the appliance that are not authorised by general contract conditions, published on the website www.carel.com...
Page 4
Warranty on materials: 2 years (from production date, excluding consum- ables). Approval: the quality and safety of CAREL products are guaranteed by the ISO 9001 certifi ed design and production system, as well as the marks.
Index 1. PURPOSE OF THE MANUAL ........7 2. HOW TOREAD THE MANUAL ........7 3. General safety information and instruction ..8 2.1 Uso previsto ......................8 2.2 Istruzioni generali di sicurezza ..............8 2.3 Dispositivi di protezione individuale ............9 4. Assembly ..............10 4.1 Packaging contents ..................
Via dell’Industria, 11, 35020 Brugine - Padova (Italy) Tel. (+39) 049.9716611 - Fax (+39) 049.9716600 e-mail: carel@carel.com - www.carel.com 2. HOW TOREAD THE MANUAL The manual is divided into chapters and paragraphs. Each paragraph is a sub-level of the corresponding chapter. References to headings or paragraphs are indicated by the abbreviation “Chap.
• Periodically check that the water system’s working pressure exceeds 1 bar and is below the maximum limit set for the equip- ment. If this is not the case, contact CAREL’s Technical Assistance Department or professionally qualifi ed personnel. • If the pumping station is not to be used for a long period of time, the following tasks must be carried out: - Switch the equipment’s main switch to “OFF”...
Personal protective equipment DANGER Strictly follow the instructions provided in the manual. Personal protective equipment (PPE) means any equipment intended to be worn and kept by workers in order to protect them- selves against one or more risks likely to threaten their health or safety during work, as well as any device or accessory intended for this purpose.
NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! humiFog +0300110ML - ITA Up to date version available on www.carel.com Rack drawing Tab. 4.a Semi-assembled rack RHS******* Description Quantity Water drain hose for solenoid valves See “RACK DRAWING”...
Page 11
Description Quantity Distributor assembled with solenoid valves and M12X1.5 fi ttings (or plugs) Manifolds complete with solenoid valves, barbed See “RACK DRAWING” fi tting and drain connector Guides with crossbars See “RACK DRAWING” There are 2 mounting brack- Mounting brackets with screw kit ets for each guide or crossbar Manifold fi xing brackets with screw kit See “RACK DRAWING”...
Installing the assembled rack in a duct The fi gures are purely for illustrative purposes; before starting assembly, check the confi guration of the product (see the “RACK DRAWING” supplied in the packaging). 4.2.1 Possible confi gurations Configuration with manifolds mounted Configuration with manifolds mounted vertically and water inlet on the left horizontally and water inlet on the left...
Page 13
4.4.1 Procedure for installing the assembled rack in a duct 84,5 The mounting brackets sup- plied as standard guarantee the incline towards the drain; use the mounting brackets supplied with the specifi c rack. Fix the mounting brackets on suitable supports. DO NOT dam- age the inside of the ducting.
Page 14
Not supplied. Fig. 4.a After installation, complete the electrical wiring between the rack and the junction box (if featured), or between the rack and the pumping station or zone panel. After installation, complete the water connections between the rack and the humiFog pumping station. humifog Rack +0300110IE rel.
Installing the semi-assembled rack in a duct The fi gures are purely for illustrative purposes; before starting assembly, check the confi guration of the product (see the “RACK DRAWING” supplied in the packaging) 4.3.2 Procedure for installing the semi-assembled rack in a duct The fi gures are purely for illustrative purposes;...
Page 19
84,5 The mounting brackets supplied as standard guarantee the incline towards the drain; use the mount- ing brackets supplied with the spe- cifi c rack. Fix the mounting brackets on suitable supports. DO NOT dam- age the inside of the ducting. Adjust by sliding according Screws for fi xing the mounting to the space remaining in the...
Page 20
Not supplied. Fig. 4.h After installation, complete the electrical wiring between the rack and the junction box (if featured), or between the rack and the pumping station or zone panel. After installation, complete the water connections between the rack and the humiFog pumping station. humifog Rack +0300110IE rel.
Fig. 4.i Checklist for mounting/installation rack Humifog SYSTEM NAME:___________________________ Description Notes The rack has been assembled with the water inlet on the right/left side as shown on the “rack drawing” The manifolds are connected to the distributor in the positions shown on the “rack drawing” The labels on the manifold match the labels on the distributor The distributor water inlet fi ttings have been assembled The manifolds have been fi xed to the support guides...
Need help?
Do you have a question about the humiFog RHM Series and is the answer not in the manual?
Questions and answers