Values Acc. To Iso 7176-15 For Model 1.054; Further Technical Data For Model 1.054 - Meyra Ortopedia iTravel 1.054 Operating Manual

Electronic travelling wheelchair
Table of Contents

Advertisement

Values acc. to ISO 7176-15 for mod-
el 1.054
Overall length
Overall width
Overall height
User weight (incl. addi-
tional load)
Overall dimensions
Actual seat depth
Actual seat width
Seat surface height at
front edge (without
cushion)
Seat angle
Leg angle
Back support angle
Back support height
Footplate to seat (low-
er shank length)
Static stability downhill
Static stability uphill
Static stability lateral
Dynamic stability
uphill
Arm support height
from seat surface
Back support to front
edge of arm support
Obstacle height
Minimal turning radius
Max. forward top
speed
Minimum breaking dis-
tance from top speed
Maximum range with
lithium batteries
min.
max.
970 mm
970 mm
560 mm
650 mm
870 mm
870 mm
120 kg
120 kg
150 kg
150 kg
400 mm
400 mm
440 mm 440 mm
450 mm
450 mm
95°
– °
10°
32°
460 mm
460 mm
440 mm 440 mm
3.5°
3.5°
240 mm
240 mm
350 mm
350 mm
40 mm
40 mm
650 mm
650 mm
6 km/h
6 km/h
1000 mm 1000 mm
8 km
12 km
Further technical data for model
1.054
Sound level
Protection class
Turning area
Drive controller
Engine output
(6 km/h)
Additional load
Permitted axle load
front
Permitted axle load
rear
Ground clearance drive
Empty weight (with
battery pack)
Empty weight (without
battery pack)
Transport dimensions
Length
Width
Height
Climatic data
Ambient temperature
Storage temperature
with drive batteries
(max. 1 year)
Storage temperature
without drive batteries
Steering wheel
200 x 50 mm (8" x 1.75")
Driving wheel
229 x 51 mm (9" x 2")
Drive batteries
1 x 24 V 10.4 Ah
min.
max.
62 dB(A)
IP 51
1030 mm
– mm
24 V / 45 A
2x 200 W 2x 200 W
– kg
3 kg
– kg
20 kg
– kg
80 kg
75mm
– kg
23 kg
– kg
22 kg
740 mm
760 mm
590 mm
620mm
310 mm
330 mm
-20 °C to +60 °C
-20 °C to +45 °C
-40 °C to +65 °C
puncture safe
puncture safe
Lithium ion battery
33