Millwatch / Silowatch
2

Installation Dos and Don'ts

WARNING
Isolate the electricity supply before starting work.
WARNING
The Millwatch/Silowatch Detector is permanently connected to an
electricity supply.
An external switch or circuit breaker is required. An external over
current protection device must be provided as close to the monitor as
possible.
Please read and follow these instructions carefully.
The Detector is not designed to be used in conjunction with any equipment unless
specified by LAND. The Detector and probe must not be connected to any other
devices. The protection provided by the equipment may be impaired if it is not used
in the manner specified in this document.
Provide a working platform with access
for installation and servicing.
Install the probe and Detector as
described in this document.
Install the power and signal lines in
accordance with local regulations.
Provide all of the services as stated in
the technical specification.
Remove exhaust gas and condensate to
a safe area.
Keep the Detector door closed.
Mount vertically on a dry, clean surface.
Mount upright with the fittings at the
bottom.
Use all four of the mounting brackets.
Provide certified calibration gas.
Purge and leak test the calibration gas
pipework before use. Calibration gas is
expensive!
Install the mill probe at the classifier
outlet, where there is a predictable flow
direction
Do: Install the mill probe with the
abrasion shield facing the flow of
pulverized coal
NOTE
You must install the peristaltic pump tube. It has been removed for transportation
and storage.
See Preventative Maintenance.
2
DO
DON'T
Install where there is excessive
vibration.
Mount the Detector more than 15 m
(50 feet) from the probe, as this will
increase the response time.
Loop the sample line, this will cause
condensate to collect.
Install the Detector in areas of extreme
temperature. See technical specification.
Install the flange more than 75 mm (3 in)
from the extraction point.
Exceed the maximum probe
temperature. See technical specification.
Site the analyser where the ambient
temperature is less than 0 ºC (32 ºF) or
greater than 45 ºC (113 ºF).
The probe must be situated where the
temperature will not exceed the rating of
the sample line. Unless cabinet heaters
or coolers are provided.
Install the probe where the filter can be
eroded by coal dust.
Single Stream
User Guide