6. 3 Error List

Error Number
1001
Message
To clear the display Power off the product.
Causes / Countermeasures
Check the detail numbers on the right side of the error title.
Number
001
Sensor CPU activation and continuity check at start up
002
Receive sensor CPU data at start up
003
Transmit sensor CPU data
004
Receive sensor CPU data (failed to read data)
005
Receive sensor CPU data (no data)
006
MSCC main thread abnormality ended (others)
007
Create interface buff er
008
Head check
009
Initialize MSCC
010
SCC initialization setting
011
-
012
Notifi cation to MSCC to start sleep + UI version of LED control
013
-
014
LED control to MSCC
015
Received invalid format data
016
CRC error failure notifi cation
017
SUB rising due to static electricity
018
Initialization failed at start up
101
Print speed setting
102
Strobe adjustment
103
Motor initialization
Initialization of overheat detection
104
(communication error at SCPU)
105
AC power control initialization
106
Initialize FPGA
Type of Error
Machine Error
Recycle power. Contact technical support if not resolved.
Description
6 Troubleshooting
Error Icon
LED
Light in red
Replace board
Replace board,
check/replace print head
Replace board
-
Replace board
-
Replace board
Image update, replace board
CT4-LX/HC4-LX-HC Service Manual
Buzzer
Long
sound,
one time
Countermeasure
96

Advertisement

Table of Contents
loading