Operation
Index
Name
8040:05
Module Fault Link active
8040:0C
Input Power Mode
(FSIN Module 1)
8041:01
Channel1.InputFilterTime
8041:02
Channel1.DiagTestPulseFilter
Time
8041:04
Channel2.InputFilterTime
8041:05
Channel2.DiagTestPulseFilter
Time
8050:01-0C Parameters for FSIN module
2
8051:01-05 Parameters for FSIN module
2
8060:01-0C Parameters for FSIN module
3
8061:01-05 Parameters for FSIN module
3
8070:01-0C Parameters for FSIN module
4
8071:01-05 Parameters for FSIN module
4
40
Default value/
Description
unit
TRUE / Boolean
If a module error occurs in this module, a module error is also set for
all other input modules of this TwinSAFE component for which this
parameter is also set to TRUE.
Diag test pulse /
• Diag test pulse
ENUM
• PowerMode A (Diag TestPulse active must be FALSE)
• PowerMode B (Diag TestPulse active must be FALSE)
see chapter Signal connection for inputs [} 26]
0x000A / 0.1 ms
Input filter of the safe input. Following this time the internal input signal
changes to the applied signal state.
Internal test pulses can have a length of up to 2 ms.
0x0002 / 0.1 ms
Input filter for the test pulse signal
0x000A / 0.1 ms
Input filter of the safe input. Following this time the internal input signal
changes to the applied signal state.
Internal test pulses can have a length of up to 2 ms.
0x0002 / 0.1 ms
Input filter for the test pulse signal
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
see module 1
Version: 2.0.0
EP1957-0022 and EP1957-2222