Installation manual
00825-0100-3814
4. Cut wire ends to remove excess wire.
3.7.3
Transducer assembly security seal
Use the following instructions and Figure 3-13 to install the security seal wire on
the transducer assembly.
Procedure
1. For each Transducer Assembly, install a security seal wire into and through
2. For each Transducer Assembly, insert a security seal wire into one of the
3. Adjust the security wire, removing all slack and thread into the lead seal.
4. Cut wire ends to remove excess wire.
Rosemount 3814 Liquid Ultrasonic Flow Meter
Figure 3-12: Base Enclosure security seals
A. Transmitter Electronics Enclosure
B. Security wire seals
C. Transmitter Electronics endcap security latch
D. Base Enclosure
This completes Base Enclosure security seal installation procedure.
one of the two holes of the Locking Ring bolt (Item C) and through one of
the two holes in the Transducer Retainer (Item D). Choose holes that
minimize counterclockwise rotation of the Locking Ring bolt and the
Transducer Retainer when security wire is taut (maximum wire diameter
0.06 inch; 1.5mm).
two holes in the transducer cable connector (Item F) and feed through one
of the two holes in the transducer cable nut (item E).
Electrical Installation
January 2023
61