Resetting The Overheat Protector - Harvia HPCS6U1HB Owner's Manual

Sauna heater
Table of Contents

Advertisement

Heater model
HPCS6U1HB
HPCS7U1HB
HPCS8U1HB
HPCS9U1HB
Table 3. Supply wires
1.
4x
4.
Figure 7.
Installing the wall-mounting device (1.) and the heater (2.–4.)

3.7. Resetting the Overheat Protector

If the temperature of the sauna room becomes
dangerously high, the overheat protector will
permanently cut off the supply of the heater. The
overheating protector can be reset after the heater
has cooled down. See figure 8. Please check that
the stones are piled properly.
Overheat protector of the device can go off
!
also at temperatures below -5˚C / 23˚F
(storage, transport, environment). Before
installation take the device to the warm environ-
ment. The overheat protector can be reset when the
temperature of the device is approx 18˚C / 64˚F.
The overheat protector must be reset before using
the device. See the user manual > Resetting the
Overheat Protector.
Input
Voltage
Ph
kW
6,0
240
1
6,8
240
1
8,0
240
1
9,0
240
1
6x
6x
EN
Amperage
1-Group
2-Group
connection
connection
25
16,7
28,25
18,9
33,4
22,3
37,5
25
2.
A. Connection box
B. Connection cable
A
B
Installation example
Parts not supplied
Figure 8.
Reset button for overheat protector
Min. 90 °C Copper supply wire
AWG No.
1-Group
2-Group
connection
connection
12
14
10
12
8
12
8
10
3.
2x
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hpcs7u1hbHpcs8u1hbHpcs9u1hb

Table of Contents