GAS PIPING
INSTALLATION
Gas Piping Installation
1. The installation must conform with local codes, or in the
absence of local codes with the National Fuel Gas Code as:
ANSI Z223.1—(Latest Edition).
2. Check Identification Nameplate for type of gas for dryer.
3. Check for altitude elevation of dryer.
4. Check with utilities company for proper gas pressure and gas
supply line.
5. Natural Gas Only—Check the gas pressure inlet supply to
dryer, 11 inches Water Column maximum. Manifold
Pressure—3.5 inches Water Column pressure.
6. L.P. Gas Only—Manifold pressure—13 inches Water
Column maximum.
CAUTION: Low gas pressure and intermittent gas will cause
gas ignition problems and inadequate drying of laundry.