Continental Girbau L36USS36G Owner's Manual page 38

75 lb. laundry dryer
Table of Contents

Advertisement

TROUBLE
Dryer runs, but no heat.
(continued)
Main Burners
burning improperly.
Main Burner cycles ON
and OFF.
Low or high gas flame.
Troubleshooting Chart
Troubleshooting Chart
CAUSE
Air Switch out of adjustment.
Air Switch defective.
Gas pressure too low.
Improper orifice.
Electric power to heating unit
turned OFF.
Line Fuse or Heater Circuit Fuse
blown to unit.
Defective relay.
Defective electric elements.
Defective thermostat.
Defective Safety Overload Thermo-
stat.
Lint compartment door OPEN.
Burner Air Shutters CLOSED.
Dirt in burner.
High gas pressure.
Orifice too large.
Restricted or blocked exhaust.
Direct Spark Ignition
defective.
Incorrect Main Burner orifices.
See Air Switch Adjustment Sheet.
Replace Air Switch.
Check manifold pressure and adjust to pressure
specified on Rating Plate. If this pressure cannot be
obtained, have gas supplier check main pressure.
Dryer is orificed for type of gas specified on Rating
Plate. Check with gas supplier to determine
specifications for gas being used. If different from
Rating Plate, contact factory and obtain proper
orifices.
Turn power ON.
Replace fuse.
Replace relay.
Replace elements.
Replace thermostat.
Replace thermostat.
CLOSE door.
OPEN for blue flame.
Blow out.
Adjust gas pressure per Rating Plate.
Send to factory for correct orifices.
Clean exhaust.
Replace Direct Spark Igniter.
Replace orifices. Check factory for correct size.
Page 38
REMEDY

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents