Continental Girbau L36USS36G Owner's Manual page 45

75 lb. laundry dryer
Table of Contents

Advertisement

NEED TO ADJUST
SHUTTER
NEED TO
PROVIDE
CORRECT
AIR FLOW
THROUGH THE
DRYER
Burner Air Inlet Shutters Adjustment
Need to Adjust Shutter
Burners Air Inlet Shutters are adjusted insufficient; air is admitted
through the burner. Flame pattern is straight up and flame is yellow.
Need to Provide Correct Airflow Through the Dryer
This flame pattern indicates the Burner Air Inlet Shutters are correctly
adjusted, but air through the dryer is insufficient. This condition
indicates excessive lint in the lint compartment, lack of make-up air in
the room, restricted exhaust duct, or a vacuum in the room caused by
an exhaust fan.