Download Print this page

After Engine Start - BRP 912 Series Operator's Manual

Rotax engine

Advertisement

To observe

4.5) After engine start

Warming up
period
Throttle response
Page 4-8
Ed.4/January 01 2023
Reduction gear with shock absorber
Since the engine comprises a reduction gear with shock ab-
sorber, take special care of the following:
Step
Procedure
1
To prevent impact load, start with throttle lever in idle po-
sition or at the most up to 10% open.
2
For the same reason, wait for around 3 sec. after throt-
tling back to partial load to reach constant speed before
re-acceleration..
3
For checking the two ignition circuits, only one circuit
may be switched off and on at a time.
Non-compliance can result in serious injuries or death!
Do not start the engine if any person is near the engine.
Step
Procedure
1
Start warming up period at approx. 2000 rpm for approx.
2 minutes.
2
Continue at 2500 rpm, duration depending on ambient
temperature, until oil temperature reaches 50 °C (122 °
F).
3
Check temperatures and pressure.
After a full-load ground test allow a cooling run at idle speed to
prevent vapour formation in the cylinder head.