15. Remove the protective plastic sheet from the bubble. Installation is complete.
10.1
Installing a pipe mount onto a NDA-U-RMT with grounded
conduit
Note: When installing the NDA-U-RMT mount, electrically grounded, liquid tight metal conduit
must be used with extra grounding.
1.
2.
3.
4.
2023-02 | V01 |
Make ground wire using a 12 AWG stranded wire that is soldered to a 3/8" ring terminal
on one end and is bare copper on the other end. Note: The length of the wire should be
15 to 20 cms (5.9 to 7.9") long.
Add the 3/8" flat washer, ring terminal of the custom ground wire and the 3/8" split
washer to the bottom most bolt on the NDA-U-RMT.
Pull all the wires that need to connect to the AUTODOME through the NDA-U-RMT pipe
and then through 3/4" electrically conductive, liquid tight metal conduit. Note: To
minimize the amount of unprotected cables, make sure the conduit is 5 to 10 cm (2 to
3.9") from the open end of the pipe at the bottom of the NDA-U-RMT.
Add a liquid tight, 3/4" metal conduit adapter fitting with a grounding lug to the end of
the grounded conduit near the NDA-U-RMT.