6.3
Finalizing the installation
22
Wiring
➤ Route a 1/2" ID upper rim water supply
line through the access hole. Use a
1/2" NPT connection (not provided).
➤ Route a 1" ID lower bowl water supply
line through the access hole. Leave
approximately 3' of extra line attached in
order to make a flexible loop.
➤ Route #18 gauge stranded copper wire
from the DC power source (positive and
ground) through a fuse or circuit breaker.
Leave at least 18" of wire for the toilet
connection.
➤ Route wiring to the toilet location.
I
Route all other optional wiring
according to the wiring diagrams.
15
Lower Bowl
23
Water Supply
Line
Touchpad
Upper Rim
Water Supply
Line
Flush switch (9400/9500)/system status
panel (optional 9300) installation
➤ Route the touchpad or flush switch Ethernet
➤ Plug the Ethernet cable into the touchpad or
➤ Snap the touchpad or flush-switch panel onto
Ethernet
Cable
cables from the Ethernet connection on the
toilet control module through the access hole
in the wall.
flush-switch panel.
the panel bracket.
Toilets
Flush
Switch
Ethernet
Cable
EN