2-3-10. Auto White Balance Standard Data Input

Adjust the white balance reference at 3200K, and adjust the normal coeffi cient of the light value.
Subject:
Clear chart (All white frame)
Adjustment page:
6E
Adjustment address:
00 to 0F
m
. Perform "F Number and ND light Quality Correction" (Section 2-3-8) before this adjustment.
. If reading/writing data on page 6E, set data:06 to page:0, address:10, and then select page:E. By this
data setting, the page 6E can be selected.
After the data reading/writing fi nished, return the data on page:0, address:10 to "00".
. Check that the data of page:6, address:02 is "00". If not, select page:6, address:01, set data:00, and press
the PAUSE button.
Adjusting procedure
Order
Page
Address
1
2
0
01
3
6
4D
4
5
6
01
6
6
01
7
6
02
*1: The adjustment data will be automatically input to page:6E, address:00 to 0F.
Procedure after completing adjustment
Order
Page
Address
1
6
4D
2
6
01
3
0
01
EVI-HD7V
Data
Operation
Check that the picture frame is "All White Frame". If not,
perform "2-3-9. Picture Frame Setting (All White Frame)".
01
40
Wait for 2 seconds.
43
Press the PAUSE button.
41
Press the PAUSE button. (*1)
Check that the data changes to "01".
Data
Operation
00
00
Press the PAUSE button.
00
2-29