Auto White Balance Standard Data Input; Standard Data Input - Sony DCR-PC350 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC350:
Table of Contents

Advertisement

13. Auto White Balance Standard Data Input

Adjust the white balance reference at 3200K.
Subject
Adjustment Page
Adjustment Address
Note1: This adjustment should be carried out upon completion of "ND
ON/OFF Adjustment".
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
Note3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform "12. Picture Frame Setting (All White Frame)" before
this adjustment.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
1
2
0
01
3
0
10
4
5
6
01
6
6
01
7
6
02
Note5: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3
Processing after Completing Adjustments:
Order Page Address Data
1
0
10
2
6
01
3
0
01
4
5
DCR-PC350/PC350E
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
F
14 (Note2)
2E to 31
E8 to F3
Procedure
Check that the picture frame is
"All white frame". If not,
perform "12. Picture Frame
Setting (All White Frame)".
01
Set the data.
00
Set the data.
Wait for more than 2 sec.
43
Set the data, and press PAUSE
button.
41
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note5)
Procedure
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
Perform "LV Standard Data
Input".
If finish the camera system
adjustments, perform "How to
release the picture frame setting"
of "12. Picture Frame Setting
(All White Frame)".
14. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: This adjustment should be carried out upon completion of "Auto
White Balance Standard Data Input".
Note2: The data of page: 0, address: 10 must be "00".
Note3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform "12. Picture Frame Setting (All White Frame)" before
this adjustment.
Note5: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1) POWER ....................................................... CAMERA-TAPE
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5) STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
1
2
0
01
3
6
C9
4
5
6
01
6
6
02
7
0
03
8
1
Note6: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
6
C9
3
0
03
4
0
01
5
6
6-31
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Display data of page 1 (Note5)
Adjustment remote commander
F
1A, 1B
0FE0 to 1020
Procedure
Check that the picture frame is
"All white frame". If not,
perform "12. Picture Frame
Setting (All White Frame)".
01
Set the data.
10
Set the data.
Wait for more than 6 sec.
0D
Set the data, and press PAUSE button.
Check that the data changes to
"01" within 20 sec. (Note6)
1E
Set the data.
Check that the display data (Note5)
satisfies the specified value.
Procedure
00
Set the data, and press PAUSE button.
00
Set the data.
00
Set the data.
00
Set the data.
Perform "Auto White Balance
Adjustment".
If finish the camera system
adjustments, perform "How to
release the picture frame setting"
of "12. Picture Frame Setting
(All White Frame)".

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dcr-pc350e

Table of Contents