IN120 & IN220 Series
Cylindrical Lock
7
IN220 (PoE) Wiring & Installation (Continued)
Supplied by CI
B-Splice
Crimp Connector
RJ45-M
Ceiling
24AWG
Stranded
Drain
Wire for
Earth
Ground in
15' Frame
Harness
Frame-Side
Harness
Assembly
(15' length)
Cable
drain wire
concealed
in shrink
tubing
Molex-M
A
Copyright © 2016, 2019, 2021, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Certified Integrator (CI) supplies and terminates
the B-Splice connector and the
Male RJ45 connector from harness to
end user provided facility cable
To building or electrical ground
RJ45-F Jack
Cable: Cat5e or higher
Cable
: Cat5e or higher,
26 AWG stranded,
shielded, 100ohm
Molex-F
Molex-F
Molex-M
B
Wiring to TIA-568-B Standard
Patch Cable
Patch Panel to
PoE Switch
24 AWG
NOTE: TIA/EIA 568-B added
only at lock side
D
PoE
Lock
RJ45-M
C
Ground
Ring Terminal
Secured to Lock
Mounting Plate
9
Supplied by End User
PoE Switch
PoE Switch is
Terminated to
Earth Ground
Patch Panel
Approved Software
Notes:
• Connectors go on only one
way. They cannot be placed
in an incorrect position.
• Do not force and do not
offset connectors.
• Be sure they are completely
seated (flush).
• PoE power source cannot be
connected to a receptacle
controlled by a switch

Advertisement