2. TRANSPORTATION
2.3 Lifting with a crane
Never walk under a module when it is lifted with a crane.
There is always a risk that the crane or helping material may break and cause serious
injuries or death.
Please be aware of the following general points:
Only use a hoist that can manage the weight of the module!
•
Never use a hoist which is damaged!
•
Use soft straps!
•
Lift the module cautiously, without jerky movements!
•
Do not touch down hard!
•
Lifting is done in the following way:
Insert 2 bars of round iron (min. 1 ½") in the holes of the base frame and secure them.
•
Use four soft straps, push them over the iron bars and put them together in the crane
•
hook.
2.4 Storage
If the unit is not installed at once but should be stored, note the permissible storage
conditions:
Do not leave the unit standing outside, but in a building.
•
Do not remove the original packaging.
•
Protect the unit until the installation from dust, dirt and damage.
•
The air temperature in storage should be between 5 °C to 40 °C.
•
The storage should be in a non-condensing atmosphere.
•
If the unit is delivered with a separate control panel, it should be handled with special caution
and stored in a safe and dry location until the installation is carried out.
5