Peristaltic Pump Head And Motor - USC AT500H Operator's Manual

Automated treater w/loss in weight seed metering
Hide thumbs Also See for AT500H:
Table of Contents

Advertisement

AT500H TREATER

PERISTALTIC PUMP HEAD AND MOTOR

The pump stand utilizes a variable speed pump motor and special norprene pump
tubing for liquid metering. Each pump comes equipped with 1 peristaltic pump head.
Liquid will only come into contact with the inside diameter of the pump tubing and not
the pump. This allows for easy cleanup and less maintenance of the pump.
To open the pump head, rotate the lever to the left. Place the pump tubing inside the
pump head so it fits inside the notches and above the rollers (bottom, left). Rotate the
lever back to the right and close the pump head, clamping the hose inside the head
(bottom, right). Wear or fatiguing of the tubing within the pump head due to compres-
sion is normal. When tubing becomes worn or chemical rates begin to slow down,
open the pump head and move the tubing to a different position. If the entire piece of
tubing becomes worn, simply replace with a new section. When not using the pump
stand for several days or when storing, open the pump head and remove the tubing to
prevent any extra compression.
Pump Head Open
Pump Head Closed
Page 20

Advertisement

Table of Contents
loading

Table of Contents