Takex PA-450EA Instruction Manual page 2

Passive infrared sensor

Advertisement

4. WIRING
POWER
ALARM
7to28VDC
N.C./N.O.
8mA
24V(AC/DC)
non-polarity
0.25A
5. INSTALLATION
1. Loosen cover lock screw and detach the cover.
2. Open knockout hole.
3. Install the base on the wall.
*Two mounting pitches are available.
*When installed on wall corner, make use of knockouts on sides.
4. Connect wires to terminals (Refer to 4. WIRING)
*Plug up an opening of wiring hole .
5. Attach the cover, and tighten cover lock screw.
7. MODE SETTING
Sensor operation can be changed by mode selector on PWB unit.
:
(*)
factory set
1 : Alarm LED
OFF
(*)
LED disabled
Alarm LED OFF:
LED operates according to alarm memory function.
2 : Alarm memory
OFF
(*)
No operation
Auto reset operation :
When an alarm has been activated, the alarm LED blinking for 3 min. and
then remains lit for 47 min. It automatically reset and memory is also
canceled. In case that the sensor retriggers while its LED is lit, LED lights for
further 47 min. after that.
3 : Selection of alarm contact
N.C.
(*)
Open at alarm
8. SPECIFICATIONS
Model
PA-450EA
Detection system
Wide Angle
Coverage
12m(40') max.
Sensitive zone
18 Pairs
Supply voltage
Current consumption
Dry contact (Semi-Conductor) (N.C. / N.O. selectable)
Alarm output
Reset : Approx. 2sec.
Rating : 24V (AC/DC), 0.25A max. (protective resistance 3.3Ω)
Tamper output
Alarm LED (Red)
Coverage adjustment
Sensitivity
Pulse count
Alarm memory
Autoreset : 3 minutes blinking, 47 minutes lighting and automatically reset
Ambient temperature range
Mounting position
Indoor use only (ceiling mount with optional attachment BCW-401)
Weight
Appearance
*The specifications are subject to change without notice.
Limited Warranty :
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of
shipment. Our warranty does not cover damage or failure caused by Acts of God (including inductive surge by lightning), abuse, misuse, abnormal usage,
faulty installation, improper maintenance or any repairs other than those provided by TAKEX. All implied warranties with respect to TAKEX, including
implied warranties for merchantability and implied warranties for fitness, are limited in duration to 12 months from original date of shipment. During
the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts returned prepaid. Please provide the model
number of the products, original date of shipment and nature of difficulty being experienced. There will be charges rendered for product repairs made
after our Warranty period has expired.
In Japan
Takenaka Engineering Co., Ltd.
83-1, Gojo-Dori, Sotokan Nishi-iru, Higashino,
Yamashina-ku, Kyoto 607-8156, Japan
Tel : 81-75-501-6651
https : // www. takex-eng. co. jp /
TAMPER
Allowable wiring distance between
N.C.
sensor and power source
30V DC
0.1A
●The maximum wire length, when two or more units are connected, is the above distance divided by
the number of units.
●The protection circuit can be wired up to a distance of 1,000m(3,280 ft ) with AWG 22 (0.65mm dia.)
wire.
ON
Lights at alarm
ON
Auto reset operation
N.O.
Close at alarm
PA-450PIA
Passive infrared
Wide Angle
12m(40')max.
29 Pairs
7 to 28V DC (non-polarity)
8mA max.
N.C. 30V DC 0.1A
: Blinking at warming up
Lighting at alarm (LED disabled)
: Blinking at memory activated (3 min.)
Lighting at memory indication (47 min.)
Vertically 3 steps
60%/80%/100%/120% selectable
1/2/3/4 selectable
-15°C to + 55°C (+5°F to + 131°F)
without condensation
90g (3.2oz)
Body : resin(white)
Lens : resin(white)
In the U.S.
Takex America Inc.
1810 Oakland Rd, Suite F,
San Jose, CA 95131, USA
Tel : 408-747-0100
Fax : 408-734-1100
https : // www. takex. com
Size of wire used
AWG 20 (Dia. 0.80mm)
AWG 18 (Dia. 1.00mm)
6. OPERATION
1. Turn the power ON, and wait for approx. 1 minute until the alarm LED stops
blinking.
2. Walk test in the protection area to check if an alarm is activated. Check on
both of the alarm LED and control panel.
It is important to check operation whenever the area of protection is changed.
3. After correct operation has been confirmed, turn the alarm LED OFF with
mode selector on PWB unit. (When set at OFF, the alarm LED does not light
even if an alarm is activated.)
4,5 : Sensitivity
60%
80%
6,7 : Pulse count
1
2
(*)
count [1]
: Most sensitive.
count [2]
: Normally set to this position.
count [3]/[4] : Least sensitive, prevents false alarms caused by temperature
fluctuation.
*Do not use count [3]/[4] for Vertical curtain(PA-460EA).
8 : Walk test mode
(*)
OFF
Walk test mode ON :
After warming up or turning on the switch, the LED lights when the sonsor
detects for 5 minutes, the alarm memory is not accepted for 5 minutes as well.
After 5 minutes, the LED function follows "Alarm LED" settings.
9. EXTERNAL DIMENSIONS
PA-460EA
■PA-450EA / PA-450PIA
Vertical curtain
18m(60') max.
70(2.76")
6 Pairs
1/2 selectable
In Australia
Takex America Inc.
4/15 Howleys Road, Notting Hill,
VIC, 3168
Tel : +61 (03) 9544-2477
Fax : +61 (03) 9543-2342
https : // www. takex. com
Distance at 12VDC
1,700m(5,600 ft.)
2,700m(8,800 ft.)
100%
(*)
120%
3
4
ON
unit : mm(inch)
■PA-460EA
45(1.77")
70(2.76")
In the U.K.
Takex Europe Ltd.
Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel : (+44) 01256-475555
Fax : (+44) 01256-466268
https : // www. takex. com
2021.8.26