Download Print this page
Takex PA-450EA Instruction Manual

Takex PA-450EA Instruction Manual

Passive infrared sensor

Advertisement

Quick Links

We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly
installed. Please read this Instruction Manual carefully for correct and effective use.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God ( including inductive
surge by lightning ), abuse, misuse, abnormal usage, faulty installation or improper maintenance.
1. PARTS DESCRIPTION
Cover
Lens
[ PA-450EA ]
Cover lock screw
[ PA-450PIA ]
2. DO'S AND DON'T'S
Install the sensor in a location such that intruders are more likely
to cross the protection zones, not to approach head on.
Do not install in a site which is subject to electrical noise or intense
vibration.
Avoid direct sunlight, spot light or intense reflections on the sensor
or the protection zone.
Do not install the sensor outdoors (indoor use only).
Do not install the sensor directly on the ceiling.
(For ceiling mount, use optional attachment BCW-401.)
3. COVERAGE AND RANGE
■Wide Angle (PA-450EA)
unit : m (ft)
Side view
Index
2.5m
(8.2')
0
5m
(10')
(20')
Factory Set
2.5m
(8.2')
5m
0
(10')
(20')
2.5m
(8.2')
5m
0
(10')
(20')
PASSIVE INFRARED SENSOR
Wide angle protection
Wide angle protection
Vertical curtain protection : PA-460EA
Instruction Manual
Base
Wiring hole
(Knockout)
Lock screw
Index
Mounting hole
(Knockout)
[ PA-460EA ]
■Vertical Curtain (PA-460EA)
AREA ADJUSTMENT
Loosen the lock screw and
move the inner PCB upwards
by using the index as a guide
in order to shorten the
coverage of senor.
(PA-450EA,PA-460EA)
2.5m
(8.2')
10m 12m
0
(30')
(40')
(10')
2.5m
(8.2')
10m 12m
0
(30')
(40')
(10')
2.5m
(8.2')
10m 12m
0
(30')
(40')
(10')
: PA-450EA
: PA-450PIA ( 40 lbs PET IMMUNE )
Terminals
Tamper
switch
Alarm LED
(Red)
Mode
selector
The passive infrared sensor is designed to detect infrared energy variations
caused by the presence of a human body.
variations in conditions in protection area, due to other reasons, may cause
the sensor to create an alarm as it is unable to distinguish the sources.
[MAINTENANCE]
When the unit is soiled, clean the cover with a soft cloth moistened with a
small amount of cleansing solution. Do not use chemicals such as thinners
or alcohol.
Check operation once a week. Do not fail to check operation whenever furniture
in coverage area is moved.
Matched to the
edge
Index
15m
5m
10m
(50')
(20')
(30')
(40')
Factory Set
15m
5m
10m
(20')
(30')
(40')
(50')
5m
10m
15m
(20')
(30')
(40')
(50')
Recessed
Wiring hole
Back View
Therefore, note that similar
■Wide Angle (PA-450PIA)
2.5m
(8.2')
18m
0
5m
(10')
(20')
(60')
Factory Set
PET IMMUNITY (PA-450PIA)
●To maintain maximum pet immunity,
install the sensor 2.5m(8.2ft) from the
18m
floor vertically without moving the
(60')
inner PCB (factory set).
●Use the optional mounting bracket
"BCW-401" to optimize
the pet immunity
18m
performance, when
(60')
area adjustment is
required.
Exposed
wiring hole
Corner
mounting
hole
10m
12m
(30')
(40')
BCW-401

Advertisement

loading

Summary of Contents for Takex PA-450EA

  • Page 1 Vertical curtain protection : PA-460EA Instruction Manual We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly installed. Please read this Instruction Manual carefully for correct and effective use. Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
  • Page 2 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced.

This manual is also suitable for:

Pa-450piaPa-460ea