Download Print this page
Takex PA-4810E Instruction Manual

Takex PA-4810E Instruction Manual

Passive infrared sensor

Advertisement

Quick Links

We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly installed.
Please read this Instruction Manual carefully for correct and effective use.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge by lightning),
abuse, misuse, abnormal usage, faulty installation or improper maintenance.
1
PARTS DESCRIPTION
MODE SELECTOR
WIRING CHANNEL
MIRROR UNIT
ALARM LED /
MEMORY LED
(Red)
2
PRECAUTIONS
This indicates the possibility of severe injury, and
Warning
even death, if ignored or a user handles the unit
incorrectly.
This indicates the possibility of minor injury and/or
damage to properties, or of a notification delay in your
Caution
system due to false operations and/or non-detection, if
ignored or a user handles the unit incorrectly.
We categorize these precautions throughout the manual using
the following symbols.
A prohibited action, you must not do.
An action you must do, and information you should keep in mind
Warning
Do not disassemble or modify this device. This
may cause a fire, electrical shock, or malfunction
of the device.
If the following events occur, turn off the power of
the unit immediately, and ask the place of
purchase for repair. Failure to follow this may
result in fire, electric shock, and/or malfunction.
• Smoke, abnormal odor, and/or sound are found
• Liquid, such as water, and/or foreign material
has entered the unit
• The unit has deformed and/or damaged parts
Mount the unit on a solid ceiling or wall surfaces
where reinforcement materials are used. If you
mount the unit on non-wood materials of plaster
board or concrete, securely mount it using
anchors and mounting screws that match the wall
materials. Unstable mounting may result in injury
and/or property damage if the unit falls.
Do not install this device in a location that cannot
support its weight. This may cause the device to
fall and cause an injury or malfunction of the
device.
Do not use the unit with power voltage levels
other than those specified. Failure to follow this
may result in fire, electric shock, and/or
malfunction.
Use the sensor lock to fix the sensor unit for
operation.
This can prevent injuries, and/or damage to the
unit if the unit falls, as well as prevent the sensor
from being tampered.
Do not connect devices that exceed the indicated
capacity to the output contact of the unit. Failure
to follow this may result in electric shock, fire,
and/or malfunction.
Do not touch terminals with wet hands. Failure to
follow this may result in electric shock.
PASSIVE INFRARED SENSOR
PA-4810E
(WIDE ANGLE)
Instruction Manual
HEAD UNIT
HORIZONTAL
ADJUSTMENT
TAMPER SWITCH
Be sure to observe
Do not apply impact to the unit.
Strong impact may result in performance
deterioration and/or damage to the unit.
The unit may not operate properly near devices
that generate a strong electric or magnetic field.
Also, devices near the unit may not operate
properly due to the magnetic field and/or
magnetism generated from the unit.
Make sure to confirm before operation.
Make sure to perform a sufficient operation
check on the whole system before operation.
Avoid installing the unit in the following places.
Otherwise, non-detection and/or false detection
may occur.
• Places subject to strong direct or reflected light
(sunlight,spotlight)
• Places subject to rapid temperature fluctuations
(air outlets of air-conditioning equipment, etc.)
• Places where moving objects are included in
the protection area (plants, laundry, etc.)
• Places subject to strong vibration and/or
electric noise
• Places where pets, such as dogs and cats,
and/or automatic cleaning robots may pass
• Places where shielding objects (including glass
and transparent resin, etc.) are included in the
protection area (shading parts will not be
detected)
• Places that people can easily touch.
Facing the window
Plants/Curtain
Refer to the protection area figures, and select
the installation location. Then, check the actual
operation, and adjust the appropriate area.
Make sure to check operation when you move
tables and partitions and change the layout in
protected rooms.
・PA-4820E
BASE
Accessories
Self-tapping screw
(ø4 x 30)
: 2 pcs
Instruction manual
: 1 pc
This manual describes precautions by classifying them based on degrees of danger and
damage that would be generated if using the unit incorrectly.
Caution
Refrigerator
Shielding objects
(LONG RANGE)
COVER
COVER LOCKING SCREW
Passive infrared sensors are
designed to catch changes of
far-infrared ray energy.
Energy changes largely when
the human body moves
across the protection area,
which is easy to detect.
However, energy does not change greatly
when the human body comes closer in a
straight line, or stops, which may be difficult to
detect. In addition, if the protection area
environment generates similar changes due to
certain factors, the unit will set off an alarm
without being able to judge properly.
Do not install the unit in places subject to oil
smoke or steam, high humidity, and/or a lot of
dust.Electricity
that
travels
through
substances may result in fire, electric shock,
and/or false operation.
Ask qualified personnel for any electrical work
necessary for installation, if required.
Failure to follow this may result in fire and/or
electric shock.
Securely conduct installation work according to
the instruction manual.
Also, make sure to use the supplied
accessories and specified components.
Failure to follow this may result in injury and/or
property damage in the event of fire, electric
shock or fall of the unit.
This unit is for indoor use. Do not use the unit in
places subject to water and/or high humidity.
Failure to follow this may result in malfunction if
water gets into the unit.
This unit is not a waterproof (moisture
proof/rainproof) or dust-proof structure. Do not
use the unit in places subject to water and/or
high humidity, such as bathrooms, and/or
subject to large amounts of dust or sand.
Failure to follow this could result in malfunction.
Do not perform aerial wiring of power and signal
cables.
Failure to follow this may result in electric shock,
fire, and/or malfunction.
Do not install the sensor
directly on the ceiling
(When installed on ceilling,
use optional attachment
BCW-401)
these

Advertisement

loading

Summary of Contents for Takex PA-4810E

  • Page 1 (LONG RANGE) Instruction Manual We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly installed. Please read this Instruction Manual carefully for correct and effective use. Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
  • Page 2 COVERAGE INSTALLATION WIDE ANGLE LONG RANGE 〈PA-4810E〉 〈PA-4820E〉 Detach the cover. Connect wires. Loosen screw until *Break the knockout and cover slips. pull in the wire through it. When using the upper CAUTION : Do not remove screw from wiring knockouts, route cover.
  • Page 3 Check alarm LED and control panel for sensor operation. TROUBLESHOOTING Analyze possible problems according to the following table. If normal operations cannot be restored by this means, contact either the dealer from whom you bought the unit or TAKEX. Trouble...
  • Page 4 Limited Warranty : TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in duration to 12 months from original date of shipment.

This manual is also suitable for:

Pa-4820e