Technical Data; General Specifications - Festo MPS 8046521 Getting Started

Programming module
Table of Contents

Advertisement

Available languages

Available languages

Programming module

6 Technical data

6.1 General specifications

Parameter
Operating pressure
Operating voltage
Digital inputs/outputs
Inputs:
Outputs:
Electrical connection
Pneumatic connection
Valve types
Sensors
Dimensions
Subject to change
42
4
4
The Pogramming module is only to be operated with Festo Didactic power supply
units (order no. 8049382 or 8049633).
Value
600 kPa (6 bar)
24 V dc
Max. 24 V dc
Max. 2 A per output
Max. 4 A total
Sub-D HD 15 (3 rows)
Plastic tubing with 6 mm outside diameter
5/2-way solenoid valve, bistable
5/3-way solenoid valve, monostable,
mid-position exhausted
4x Proximity sensor
1x Optical diffuse sensor
1x Capacitive proximity sensor
210 mm x 140 mm x 410 mm
© Festo Didactic 8046514