4. SIP message summary (INFO level)
5. Inbound and outbound calls (INFO level)
6. Registration status change (INFO level)
7. Negotiated codec (INFO level)
8. Ethernet link up (INFO level)
9. SLIC chip exception (WARNING and ERROR levels)
10. Memory exception (ERROR level)
11. Extra syslog style (EXTRA DEBUG level)
Example: In the process of configuring a Syslog server, the steps are to define Syslog protocol and set it to
UDP or SSL/TLS, enter the IP Address of your host machine define the Syslog level based on the information
required (DEBUG, INFO, WARNING...), 
Send SIP
Configures whether the SIP log will be included in the Syslog messages.
Log
The default setting is No.
Allows the device to make a packet capture, by clicking the capture button, when that is set, the user can
define the following:   
1. With Secret Key information: Allows users to make packet capture including the secret key to decrypt the
Information
captured TLS packets., set to "No" By Default
Capture
2. Status: Set to "Idle" when the packet capture is not started and to "Running" when packet capture is
enabled.
3. Capture file: stores the registered Captured file and make it ready for download. 
Default is No. When "Yes, reboot every day at hour" or "Yes, reboot every week at day" or "Yes, reboot every
Automatic
month at day" is checked, user can specify "Hour of the day (0-23)" or "Day of the week (0-6)" or "Day of the
Reboot
month (0-30)". Default time is Monday 1AM.
Download
Allows user to download and save a text file containing all the P values of each setting as configured at that
Device
Configurati
point on the unit. For Security Reasons, Passwords will not be Downloaded.
on
Download
Allows user to download and save an XML file containing all the P values of each setting as configured at that
Device XML
Configurati
point on the unit. For Security Reasons, Passwords will not be Downloaded.
on
Upload
Allows the user to upgrade the firmware with a single firmware file by browsing and loading the file from your
Firmware
computer (local directory).
Upload
Allows to upload configuration file to the device.
Configurati
on
Export
Download backup file to local computer.
Backup
Configurati
The backup file is XML and encrypted.
on
Restore
From
Backup
Uploads the backup file to the ATA to restore your saved configuration
Configurati
on