10 Cleaning and Disinfecting
If the Confidence Plus Germicidal Cleaner is not used, wash components in a mild cleaning solution and make sure to rinse
them thoroughly. When cleaning the respirator in normal weather, submerge the facepiece in a germicide solution for the
manufacturer's recommended time.
10.1

Facepiece

WARNING!
• Do NOT use cleaning products that contain hydrocarbons or solvents such as nitro-thinner.
• Do NOT use radiant heat such as the sun or radiators to dry cleaned parts.
• When a drying cabinet is used, make sure that the temperature is not more than 140°F (60°C).
• Do a negative pressure seal test after every cleaning, disinfecting, and maintenance procedure, and after every
exchange of parts.
Failure to follow these warnings can result in serious personal injury or death.
It is only necessary to clean and disinfect the facepiece after each use.
1. Use the instructions on the label to prepare a solution of Confidence Plus Germicidal Cleaner (PN 10009971) in a
bucket or sink.
2. Remove the air filtration cartridges/canisters from the APR adapter.
3. Remove the APR adapter from the facepiece.
NOTE: The head harness can be cleaned as part of the facepiece or removed to
be cleaned separately.
4. Submerge the facepiece in the solution of Confidence Plus Germicidal Cleaner for
a minimum of 30 seconds.If necessary, use a soft brush or sponge to clean the
facepiece.
G1 APR Facepiece
US
28