Donning; Donning In Normal Weather - MSA G1 Operating Manual

Air-purifying respirator full facepiece respirator
Hide thumbs Also See for G1:
Table of Contents

Advertisement

7 Donning

When used at specified occupational exposure limits, do NOT exceed the rated service time.
1. Remove the air filtration cartridges from the packaging.
2. Make sure that the air filtration cartridges are not damaged.
3. Make sure that the air filtration cartridges are applicable for use against all contaminants in the environment.
4. Look at the label on the air filtration cartridges to make sure that the shelf life has not expired. If the shelf life has
expired, do NOT use the air filtration cartridges.
7
Donning
WARNING!
• If you have a beard, large sideburns, or similar physical characteristics that prevent direct contact between your skin and
the sealing surface of the facepiece, this device may not seal correctly with your face (refer to NFPA 1500, Standard on
Fire Department Occupational Safety and Health Program, and ANSI Z88.2, Practices for Respiratory Protection). An
incorrect facial seal can let contaminants leak into the facepiece, decreasing or removing respiratory protection. Do NOT
use this device if such conditions exist.
• Do a negative pressure seal test before each use and before going into a toxic atmosphere.
• Make sure that the correct nosecup is installed in the facepiece. Refer to the G1 APR Approval Insert (PN 10160485) for
information about approved configurations.
• Individuals who wear eyeglasses must use the G1 spectacle kit to guarantee a correct fit. Ordinary eyeglasses cannot
be worn under the facepiece.
• Wear impermeable protective clothing to prevent exposure to gases and vapors that can poison by skin absorption.
• Only remove the respirator in a safe, nonhazardous, nontoxic atmosphere.
Failure to follow these warnings can result in serious personal injury or death.
Make sure that the APR adapter and applicable air filtration cartridges/canisters are installed before you don the respirator.
When the respirator is adjusted correctly, the user should not taste or smell the contaminant, or feel irritation of the eyes, nose,
or throat. The user's inhalation resistance should be as experienced during training.
7.1

Donning in Normal Weather

WARNING!
• Make sure that the top of the facepiece seal is in direct contact with your forehead.
• Make sure that there is no hair between the facepiece seal and your skin.
Failure to follow these warnings can result in serious personal injury or death.
5. Attach the air filtration cartridges to the facepiece port.
a. Align the small lug on the connector with the match-mark on the cartridge
body to mate the cartridge cutouts with the bayonet lugs.
b. Turn the cartridge clockwise until tight.