G1 Spectacle Kit; Size Selection; Respirator Fit Test - MSA G1 Operating Manual

Air-purifying respirator full facepiece respirator
Hide thumbs Also See for G1:
Table of Contents

Advertisement

US
2.5

G1 Spectacle Kit

3

Size Selection

NOTE: Individuals who wear eyeglasses must use the G1 spectacle kit to guarantee a correct fit. Ordinary eyeglasses cannot
be worn under the facepiece.
Regardless of facial dimensions and respirator sizing charts, users must do an actual qualitative or quantitative respirator fit
test to make sure that the correct respirator size is selected.
1. Do a fit test of the respirator size relative to your facial features and dimensions. Ask the safety administrator or program
manager for help selecting the initial size to try.
2. Don the respirator. Refer to
3. Do a negative pressure seal test. Refer to
4. If the respirator does not pass the negative pressure seal test or feels uncomfortable, try the next nearest size relative to
your face.
5. Passing the negative pressure seal test does not verify that the size is correct. Do a qualitative or quantitative respirator
fit test to verify the size. If the respirator passes a negative pressure seal test but does NOT pass a respirator fit test, try
the next nearest size.
3.1

Respirator Fit Test

WARNING!
• Do quantitative or qualitative respirator fit tests routinely for each wearer of this respirator.
• Obey all specified warnings and limitations.
Failure to follow these warnings can result in serious personal injury or death.
Refer to ANSI Z88.2 latest version, Practices for Respiratory Protection, and Title 1910.134, Respiratory Protection Standard,
for information about respirator fit tests.
In addition to regular respirator fit tests, do a qualitative or quantitative respirator fit test after repairs or maintenance.
NOTE: The selection of a fit test method can have an effect on the maximum use concentration.
Use the instructions and adapter in a Quik Chek Kit (PN 805078) to do respirator fit testing.
13
The G1 spectacle kit lets users mount eyeglasses inside the facepiece. Individuals who
wear eyeglasses must use the G1 spectacle kit to guarantee a correct fit. Eyeglasses
cannot be worn under the facepiece without the G1 spectacle kit.
7 Donning
for instructions.
7.3 Testing the Negative Pressure Seal
G1 APR Facepiece
3 Size Selection
for instructions.