3-
4.
6
Enter the
DUT's
serial prefix number (This
Is
the first
five
alpha-numeric characters
in
the
instrument's serial number (i
e,,,
2231A).
If
test data
for this
instrument exists on
the
current data
disc (from previously run tests), the
computer won't
ask for the
serial prefix
number.
Enter the
DUT's
option configuration. Refer
to
the serial tag on the
rear panel of
the
DUT
and one
at
a
time, enter the three
digit
option numbers shown
on
the
serial
tag (many
instruments only have one option, or none at
all)
Once
all
the options have been entered,
press
enter.
If
the instrument
is
a
standard (ie..,
no options listed),
just press enter
If
test
data for
this
instrument exists
on the
current data
disc (from previously run tests), the
computer
will
not ask
for option information.
If
the option information had to be
entered
In
step 4, the
computer
will
now display the
options that
were entered
(000
will
be displayed
if
no options were entered)
If
the
list is
correct, press Yes,
if
not,
press No and re-enter the option configuration when prompted.
The software
will
now give
you
a
choice of the following-
7.
-
Allows
you
to access
the
test menu for
the type of testing you
selected
(ie,,,
either
Operation
Verification or
Attenuator Calibration).
Menu
-
Tells the
software that
you have connected
a
different
DUT
to the
HP-IB Note that
if
the model number of the new DUT
is
not the same
as the previous one, the program
will
automatically
return you to the
8340 FAMILY TEST SYSTEM
menu
New OUT
If
Menu
Is
selected, the test menu name and the tests which may be
run will be
displayed.
At
this point,
select the appropriate softkey- You have the following choices:
Input
#
-
Allows you
to
enter the specific test number you wish
to run
Auto
-
The auto sequence menu allows you
to select which tests to run
Sequence
automatically. When the
tests
are selected (ON or All on softkey
and
then
the
Execute softkey
are pressed), the
program
will
automati¬
cally load the first test At the end of each test, the next test
will
then
be
loaded This feature saves
having
to
return
to the
test menu after
each
test.
LoopTest
-
Allows
you
to
run the
selected test (test the cursor
is
pointing to)
however many
times you wish The cursor position can
be
changed
by using the rotary control knob on the keyboard or the
up/down
keys.
PrevPage
-
Not
implemented
on
this
version of software
Utility
-
Allows you to access
the
Test Menu
Utilities
(see Chapter
16
for
detailed Information on how
to use the utilities
described below)
The
Utilities
which you may choose from are as follows:
*
Change the
option configuration Cal Constants
in
the DUT (used
when retrofitting
options).
*
Display or print the data from any of the tests you have
run.
*
Display or print the test status for any instrument you
have tested.
Testing an
HP
8340A/B
or
HP 8341A/B
HP 8340A/B
and
HP 8341A/B

Advertisement