Changing The Oil In The Exciter Housing - Fayat Group DYNAPAC DFP7AX Operating Instruction

Single direction vibratory plate
Table of Contents

Advertisement

Maintenance – Annually
Fig. 84
Fig. 85
Fig. 86

8.8.6 Changing the oil in the exciter housing

92
6.
Secure the coil against winding up. For this purpose tie the
coil (2) to the housing (5) with a cable strap (1).
7.
Untie the knots of the starter rope at both ends and remove
the old starter rope.
8.
Thread in the new starter rope (3) and fix it with knots on
both ends.
9.
CAUTION!
Danger of injury caused by the starter
handle hitting against your body!
Do not let the starter handle hit back.
Remove the fixing of the coil and run the starter handle
slowly back to initial position.
10.
Pull the starter handle to check the function and light move-
ment of the recoil starter.
11.
Assemble the recoil starter.
NOTICE!
Components may get damaged!
Use only oil of the permitted specification
Ä Chapter 8.3 „List of fuels and lubri-
cants" on page 77.