Checking, Cleaning The Spark Plug - Fayat Group DYNAPAC DFP7AX Operating Instruction

Single direction vibratory plate
Table of Contents

Advertisement

Maintenance – As required
Fig. 95
1
Fig. 96

8.9.5 Checking, cleaning the spark plug

98
1.
Check condition and tension of the V-belt, tighten if neces-
sary.
ð Compression measurement: 5 - 10 mm (0.2 - 0.4 in).
2.
If necessary, tighten the V-belt; if damaged, replace the V-
belt
3.
Assemble the V-belt guard (1) with fastening screws (2).
2
B-230-0072
Protective equipment:
Special tool:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 64.
2.
Allow the engine to cool down for at least 15 minutes.
DFP7AX
Ä Chapter 8.8.4 „Replacing the V-belt" on page 89.
NOTICE!
Danger of engine damage!
Do not use spark plugs with incorrect heat
value.
n
Working clothes
n
Protective gloves
13/16 inch spark plug spanner
n
Ä Chapter 6.5