Honeywell HON 380 User And Maintenance Instructions page 34

Gas pressure regulator with controller
Table of Contents

Advertisement

Specific setpoint
range
W
[mbar]
ds
1000 - 2000
1500 - 2000
Adjusting the control
stage setpoint
HON 380 gas pressure regulator with HON 673/674 controller
RE0
Wire di-
Part no.
ameter
[mm]
10009163
12
10009164
13
Proceed as follows:
Figure
*RE1
*RE1
**RE2 and RE0
Compression spring
RE1
Wire di-
Part no.
ameter
[mm]
Step
1
2
3
Adjusting the settings of the device
RE2
Wire di-
Part no.
ameter
[mm]
Description
Remove the cap (1) of the diaphragm
housing.
*) Only for RE1 versions.
Open the inlet shut-off device.
*) Turn the spring adjuster in small in-
crements until the pressure gauge in
the outlet chamber shows the set-
point for the correct outlet pressure
p
.
d
Turn the spring adjuster
 Clockwise (+) to tighten the pilot
spring
or
 Counterclockwise (-) to loosen the
pilot spring
**) Turn the spring adjuster in small
increments until the pressure gauge
in the outlet chamber shows the set-
point for the correct outlet pressure
p
.
d
Turn the spring adjuster
 Clockwise (+) to tighten the pilot
spring
or
 Counterclockwise (-) to loosen the
pilot spring
Color
White
Green
34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hon 673Hon 674

Table of Contents