Download Print this page

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
AND SAFETY INFORMATION
FO T E V I K I N G
C L A S S I , C L A S S I I , C L A S S I I I ,
A N D C L A S S I V
Residential and Commercial
Vehicular Slide Gate Operator
1 0 GAT E O P E ATO
VIKING BLUE ENABLED
SOLAR EFFICIENT OPERATION

Advertisement

loading
Need help?

Need help?

Do you have a question about the H10SPS and is the answer not in the manual?

Questions and answers

Summary of Contents for Viking H10SPS

  • Page 1 1 0 GAT E O P E ATO C L A S S I , C L A S S I I , C L A S S I I I , VIKING BLUE ENABLED A N D C L A S S I V...
  • Page 2 The 10 gate operator has the capacity to operate slide gates up to 2200 lbs. and 7 ft. in length at 100 duty cycle under extreme conditions. This efficient operator provides a solution for high traffic commercial slide gate applications. The Viking 10 gate operator offers efficiency and technology combined in a single package. THE VIKING H-10™ SWING GATE OPERATOR...
  • Page 3 H-10 Vehicular Gate Operator • Revision H10NXMN10.A • November 2012...
  • Page 4 DUMRS10 EMI Fuse Holder & Harness VNXEFHH Fuse - 4 amp VNXF4A Fuse - 20 amp VNXF20A 25’ #40 Chain Kit, Nickle Coated VAL3CKN Motor Harness VNXH10MH Power Harness VNXL3PH Brush Kit VAMBK Loop Rack VA-LR VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 5 7. EPS (ELECTRONIC POSITIONING SENSOR) main power supply protection sensor for the digital limits 16. MODULAR POWER BOX 8. MOTOR removable; provides a convenient solution for optional low voltage installations 9. LOOP RACK for convenient loop detector installation VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 6 5. “EPS1” CONNECTOR wired master/slave connection. pg 22 connections for Viking Blue, Viking available for future developments Cell, Viking WIFI and VIKING RF. pg 44 16. CONTROL BOARD MOUNTING HOLES 6. “EPS2” CONNECTOR secures and grounds the control board. 25. “FAIL SAFE/SECURE” Jumper monitors the limit positions.
  • Page 7 Magnetic Lock, Lock Solenoid Barrier Arm (B-12) Synchronization Option TROUBLESHOOTING TROUBLESHOOTING 34-39 34-39 LED References 34-35 LCD Display References 36-38 Solutions APPENDIX A, B & C APPENDIX A, B & C 40-43 40-43 VIKING EXPANSION PRODUCTS VIKING EXPANSION PRODUCTS VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 8 5. The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving AND AWAY FROM THE GATE PATH PERIMETER. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 9 (refer to page 7). g. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). h. Only Use Miller Edge Model MGR20 or MGS20 edge sensor to comply with UL325 VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 10 • In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 11 Install the gate operator only when: The operator is appropriate for the construction of the gate and the Usage Class of the gate. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 12 • One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. Consult the installation manual for the UL325 device (photo beam or like) for detail information about the usage, installation and maintenance. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 13 1. Lift the Access Door, located on the front of the cover. 2. Press the Manual Release Switch to the “RELEASE” Position. The gate can now be moved manually. To resume normal operation, press the switch to the “ENGAGE” position. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 14 • All Warning Placards must be installed where visible in the area of the gate. • A minimum of two placards shall be in- stalled. • A placard is to be installed in the area of each side of the gate and be visible. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 15 75 ft 2200 lb. Specifications Maximum Gate Length: 75 ft. Maximum Gate Weight: 2200 lb. Operating Temperature: -20ºF (-28ºC) to 158ºF (70ºC) Power Requirements: 115v or 230v AC (4 amp) Single Phase (50 Hz / 60 Hz) VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 16 Follow the local building code to determine the required depth of the con- crete pad. 2. Pad measurements recommended by Viking Access Systems are at lease 24” long, 18” wide and 24” deep to ensure the stable operation of the op- erator, and a minimum of 4”...
  • Page 17 Also provide conduit for the power supply to the operator. DO NOT run low voltage and high voltage wiring in the same conduit. Provide at least 12 ” separation between low and high voltage conduits. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 18 4 feet (1.22 m) above the ground to prevent a 2-1/2 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 19 3”. STEP 2 Chain Installation: Before welding the provided chain brackets, make sure the chain will be in a straight line with, and at the same height as, the chain leaving the gate operator rollers. 14.375" VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 20 • Always use a single bonding point for grounding. • All ground wires must be as short and as thick as possible. • Prevent unnecessary turns or loops in all ground wires. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 21 The number of cycles achieved daily is dependent on the average solar radiation of the geographic location and the power consumption of all accessories being used. Increased panel and battery capacities may be required. See Appendix C on page 43 for more important information regarding solar applications. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 22 LED stops flashing. stops flashing. Tip: The gate can be moved electronically with the “Open”, “Stop” and “Close” buttons on the Control Board or manually by following the instructions on page 11. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 23 “Close Limit” button until the LED is flashing. until the LED is flashing. 2. Repeat STEP 2 on page 20 to set the 2. Repeat STEP 3 on page 20 to set the limit. limit. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 24 • 2 Conductor (wire) • 18 AWG or better • Shielded (overall foil) • Drain Wire (non-insulated or bare wire) Condui Drain Wire Shielded Cable Master Board Slave Board “MS1” “MS1” “MS2” “MS2” Conduit between Master and Slave VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 25 DO NOT set the “Timer” and/or “Overlap” features on both operators Control Boards. Only turn these features on at the Master Control Board. REQUIRED ADD-ON: 1. Viking Blue - Wireless Master/Slave Kit PART# VA-BLUE-MSKT Connect one Bluetooth Module, provided with VA-BLUE-MSKT, to the “V-Blue” plug &...
  • Page 26 Sets the amount of force required to trip “Speed” the inherent obstruction sensor. Motor Speed See page 26 for more details about this Increases or decreases the speed of gate feature, travel from 75% up to 150%. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 27 Safe/Secure” connector: “Sync” The gate can move Used only in conjunction with manually with a relatively the Viking Barrier gate operator model low amount of force. B-12. Activating this feature allows for • Fail Secure Mode: synchronized operation with the B-12 By inserting the wire- operator.
  • Page 28 The Status LED for the “ODS” will indicate the following when it has been triggered. A. Illuminated Solid: Detected a sudden or abrupt increase in gate resistance. B. Flashing: Detected an more subtle but sustained increase in gate resistance. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 29 For more information terminal labeled “GND” on the control regarding accessory connections board. to the control board and individual Typically, these are the transmitter/ input terminal functions, refer to receiver type photo beams. “Appendix (A)”, pages 40-41. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 30 TECHNICAL TIP: For more information regarding accessory connections and terminal functions, refer to “Appendix (A)” on pages 40-41. See “Appendix (B)” on page 42 for connecting common radio receiver models. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 31 “C” connection to “GND”. “ATG” Anti-Tailgate This input will stop the gate when the vehicle triggers the sensor, then closes the gate when the vehicle leaves the sensor, preventing unauthorized vehicles from entry. N.O. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 32 This operator may be equipped with a pre-wired Loop Rack that plug-in type loop detectors can be connected to. This provides a convenient alternative to the box type loop detectors that would need to be wired to the control board. Viking does not provide either type of loop detectors.
  • Page 33 Consult the manufacturer of the vehicular loop detector and/or loop wire. • Gate size • Number of turns in the loop sensor wire • Distance of the loop sensor wire to the gate at either at the open or close position Table C - Recommended Number of Turns Perimeter (ft.) Number of Turns 30-40 50-100 Dimension “A” - 5’ for Single Gate 6’ for Dual Gate VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 34 ACCESSORY CONNECTIONS Magnetic Lock, Lock Solenoid NOTE: Viking Access Systems does not provided the these external gate lock devices and access control. These items can be purchases from your dealer or distributor. Power Do not use the 24v DC power supplied by the control board.
  • Page 35 This type of application opens and closes in the follow pattern: 1. Open Command is provided only to the Viking B-12 Barrier Arm Operator. 2. The Barrier Arm will delay to open until this Gate Operator reaches its Open Limit.
  • Page 36 Control Board is receiving an input from a device connected to the UL 9, 10 terminal (pages 12-13, 40). “Radio” Normal Condition. SOLID Control Board is receiving an input from a device connected to the 9, 10 Radio terminal (pages 28, 40). VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 37 SOLID There is 24v DC output on these terminals at the moment. 23 “Siren” Normal Condition. 11, 13, 1, 2 SOLID Second consecutive obstruction has been detected. (page 28). 1, 2 FLASHING Batteries are critically low. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 38 Gate is waiting for the overlap time TIMING HOLDING Gate is at the limit open position and timing to close - The display shows the actual time left - prior to time-out 25 SEC EPS2 Electronic Positioning Sensor is functioning properly VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 39 ERR CHRG Potential problem with the charging voltage from the control board. 1, ? HIGH ERR CHRG a) 4 Amp Fuse is blown 15, ? b) or there is a problem with the control board CHECK 4A VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 40 ERR EMI Lightning strike protection for the EMI Board in the Modular Power Box needs to be replaced PROTECT ERR SENS Motor Current Sensor need replacement CURRENT ERR SENS Motor is not detected 7, 8 MOTOR VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 41 Check the EMI cable is properly connected to the “EMI” Connector on the control board. pg. 4 Check the LCD Display for Error Messages pg. 36, 37 The control board may be damaged. Call Viking Tech Support for assistance. VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 42 Each input Terminal (i.e. Radio, Exit, Re-Open, UL) has a corresponding Status LED that when illuminated indicates an input is currently being provided to the terminal and the gate is responding accordingly. (See page 5 for LED References) VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 43 APPENDIX (A) Relays In General NOTE: Viking Access Systems does not provided the external safety devices and access controls. These items can be purchases from your dealer or distributor. In General Glossary of Terms 1. Terminal: Wire Connections. In regards to the Viking control board, 2.
  • Page 44 Appendix (B) Common Radio Receivers - Connections VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 45 One low voltage, low current loop detector c. One low voltage, low current photo beam If more specific information is needed please consult with Viking Access Systems. For more information regarding solar energy refer to www.nrel.gov/solar VIKING TECHNICAL SUPPORT 1.800.908.0884...
  • Page 46 VIKING EXPANSION PRODUCTS Viking Bluetooth Master/Slave kit Secure and reliable wireless Master/Slave communication using Vikings bluetooth technology Part# VA-BLUE-MSKT Viking Bluetooth Diagnostic Tool Provides wireless diagnostic information while within range of the control board. Part# VA-BLUE VIKING RF-Link Wireless Master/Slave communication using a robust bidirectional radio signal.
  • Page 47 OUR CONTINUOUS COMMITMENT TO EXCELLENCE Viking Access ystems is continuously working hard to identify and design products that will appeal to the industry and it s needs. As technology continues to advance, we have developed a completely efficient and intelligent line of gate operators to meet the changing demands. These machines offer full L 2 and L...
  • Page 48 STANDARD FEATURES AND OPERATOR SPECIFICATIONS • L 2 and L 1 Compliant by nderwriter • Intelligent speed control with smooth start Laboratories ( L) standards. and stop, self ad ust system • Externally accessible Manual elease witch • Anti Tailgating and Operation Pre arming features • Fail afe option sets the gate to automatically transfer to a fail safe mode • On Board LCD Display provides diagnostics, in the event of a power failure, allowing the operator status, settings and real time volt gate to be pushed open without the use of and amp readings special knowledge of the equipment • Intelligent obstruction detection with • Fail ecure option sets the gate to ad ustable sensitivity electronically lock in the event of a power • Built in climate control for cold weather...

This manual is also suitable for: