9. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control
IMPORTANT: Ceiling fan blades MUST be installed
before high speed conditioning can begin.
Within 1 minute of restoring Electricity to the Ceiling
Fan, push and hold the Fan OFF Button (
seconds to set the Code in the Receiver.
The Ceiling Fan Lights (if installed) will blink to indicate
the Transmitter has been paired with the Receiver.
IMPORTANT: Immediately after successful pairing,
the ceiling fan will automatically begin high speed
conditioning of the motor. During conditioning, the
electronic motor control software is calculating
speeds for the 2nd through 5th speed settings
based on the blades that were installed on the fan.
The Fan will run for approximately 2 minutes in the
upward direction then reverse direction to down flow
and run an additional 2 minutes. When conditioning is
complete, the Fan will come to complete stop.
IMPORTANT: Do not interrupt the conditioning until
the fan comes to a complete stop in approximately
5 minutes. All functions of the control will be
rejected during conditioning.
) for 3 to 5
High Speed Conditioning is now complete.
If programming is unsuccessful, retry the previous
instructions after cycling the Wall Control ON/OFF
Switch to restart the 1 minute programming time period.
If still unsuccessful, shut OFF the Electricity at the Fuse
Box or Breaker Panel and change the Wall Control
Frequency (page 16). After changing the Frequency
Settings, repeat instruction #1 of this Section within one
minute of restoring the Electricity.