8. Wall Control Installation
Single-Pole Installation
(continued)
8.3
Before installing Wall Control, place Wall Control in
"OFF" mode by pushing "ON/OFF" Switch to the "OFF"
position.
Connect One Black Wire of Wall Control to the "HOT"
Wire. Securely connect Wires with Wire Connectors,
supplied (Figure 28).
Connect One black Wire of Wall Switch to the "LOAD"
(black) Wire in Wall Box. Securely connect Wires with
Wire Connector, supplied.
Screw Wall Control into Wall Box using the supplied
Screws. Leave Wall Control in "OFF" mode until Fan
installation is completed.
The Wall Control is supplied with a White, Ivory, and
Almond color Switch Covers. Choose the finish that
best suits your needs and snap the Cover onto the Wall
Control (Figure 28).
Install Decorator Wall Plate using the Two Screws
provided with Wall Plate. Leave Wall Control in "OFF"
mode until Fan installation is completed (Figure 29).
WARNING
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
(Continued)
SCREWS (2)
SWITCH COVER
DECORATIVE WALL PLATE
Figure 28
HOT
BLK
NEUTRAL
RECEIVER LOCATED ON
TOP OF THE CEILING FAN
Figure 29
18
ON/OFF SWITCH
O = OFF / — = ON
FAN/LIGHT WALL
WALL
CONTROL
BOX
NEUTRAL
WIRES
FAN/LIGHT
WALL CONTROL
BLACK
GROUND
ETL Model No.: CF788