8. Wall Control Installation
3-Way Installation
8.6
Before installing Wall Control, place Wall Control in
"OFF" mode by pushing "ON/OFF" Switch to the "OFF"
position.
Install a Wall Control in the Wall Box containing the
"HOT" Wire first. Connect the Black Wire of the Wall
Control to the "HOT" Wire. Securely connect Wires with
Wire Connectors, supplied.
Connect one Black Wire of the Wall Control to both
remaining Traveler Wires in the Wall Box and secure
with Wire Connector, supplied (Figures 32 & 33).
NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire
Is required (See Figure 33).
WARNING
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
(continued)
(Continued)
FAN/LIGHT
HOT
WALL
HI
LIGHT
MED
LOW
CONTROL
FAN OFF
EMERSON
®
OFF
ON
BLACK
TRAVELER
WIRE
NEUTRAL
RECEIVER LOCATED ON
TOP OF THE CEILING FAN
Figure 32
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
HOT
BLK
3-WAY WIRING DIAGRAM: RETROFIT
HOT
BLK
FAN/LIGHT
WALL CONTROL
TRAVELER WIRES
Figure 33
20
HI
LIGHT
MED
LOW
FAN OFF
EMERSON
®
OFF
ON
LOAD
BLACK
GROUND
EXISTING
WALL CONTROL
TRAVELER WIRES
BLK
BLK
BLK
ETL Model No.: CF788