Sharp AR-280 Service Manual page 98

Hide thumbs Also See for AR-280:
Table of Contents

Advertisement

44 - 4
Purpose
Setting
Function
Used to set the target image (reference) density level in the developing bias voltage correction.
(Purpose)
(for OPC drum type B)
Section
Image process
(Photoconductor/Developping/Transfer/Cleaning)
Item
Data
Operation/
1. Enter the set value (38) with the 10-key.
Procedure
2. Press the [OK] key. (The value entered in procedure 1 is set.)
Set value: 38
Note
It must be set to 38.
44 - 5
Purpose
Setting
Function
Used to set various parameters (main charger grid voltage, laser beam power, correction start developing bias
(Purpose)
voltage) in developing bias correction.
(for OPC drum type B)
Section
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Operation/
1. Select the parameter mode with [↑], [↓] keys.
Procedure
2. Enter the parameter with the 10-key.
3. Press the [OK] key. (The value entered in procedure 2 is set.)
GRID BIAS VOL:
DEVE BIAS VOL : Reference developing bias voltage level in patch forming (210) (Set value)
LASER DUTY:
Note
Be sure to set to the specified value. If not, the print image density may be disturbed.
44 - 9
Purpose
Operation data output/Check (Display/Print)
Function
Used to check the data on the result of the image forming section correction (process correction) (the corrected
(Purpose)
main charger grid voltage in each print mode, developing bias voltage, the laser power, etc.)
(This simulation allows to check whether the correction is executed properly or not.)
Section
Image process
(Photoconductor/Developping/Transfer/Cleaning)
Item
Data
Reference charging voltage level in patch forming (380) (Set value)
Laser duty level in patch forming (255)
8 – 53
Adjust/Setting data
Operation data (Machine condition)
AR-405
1/21/1999

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-285Ar-335Ar-405

Table of Contents