Purpose
Adjustment
Function
Used to adjust the print image center position. (Adjustment can be made for each document mode.)
(Purpose)
Section
ICU
Item
Picture quality
Operation/
1. Select the adjustment item (paper feed section) with [↑], [↓] keys.
Procedure
2. Enter the adjustment value with the 10-key.
3. Press the [OK] key to set the adjustment value entered in procedure 1.
When the set value is increased, shift is made forward. When decreased, backward.
When the set value is changed by 1, the shift is changed by about 0.1mm.
Default: 50
Note
51
51 - 1
Purpose
Adjustment
Function
Used to adjust the OPC drum separation pawl ON timing.
(Purpose)
Section
Image process
(Photoconductor/Developping/Transfer/Cleaning)
Item
Operation
Operation/
1. Enter the adjustment value with the 10-key.
Procedure
2. Press the [OK] key. (The value entered in procedure 1 is set.)
Time interval from the resist roller clutch (RRC) ON timing to the OPC drum separation pawl drive solenoid (PSPS) ON.
When the set value is increased, the timing is delayed. When the set value is changed by 1, the timing is changed by
about 1.0msec.
(Default 310)
Note
1/21/1999
Image position
8 – 70