Display; Electrical Data - JUMO miroTRON Brief Instructions

Electronic thermostat with pid two-state controller function
Hide thumbs Also See for miroTRON:
Table of Contents

Advertisement

Available languages

Available languages

8.4

Display

18-segment LCD displays
Digit height
Color
Places, including decimal places
Decimal places
8.5

Electrical data

Voltage supply
according to the ordered ver-
sion
Electrical safety
Power consumption
Type 701080
Type 701081
Accuracy of timer
Sampling rate
Electrical connection
Conductor cross section, mechani-
cal
Wire or stranded wire
(without ferrule)
Stranded wire with ferrule
Stripping length
Conductor cross section, electric
5 A load current
10 A load current
16 A load current
Upper display:
13 mm
white
4
0, 1, or automatic (configurable)
02
AC 230 V -15/+10 %, 48 to 63 Hz
05
AC 115 V -15/+10 %, 48 to 63 Hz
30
DC 12 to 24 V, -15/+15 % SELV
acc. to DIN EN 61010, part 1
Overvoltage category II to 300 V mains voltage,
Pollution degree 2
Type AC 230 V:
Max. 3.3 W
Max. 4 W
1 %
250 ms
On the back via spring-cage terminals (PUSH IN technology)
2
Min. 0.2 mm
, max. 1.5 mm
Without plastic collar: min. 0.2 mm
With plastic collar: min. 0.2 mm
8 mm
2
Min. 0.75 mm
2
Min. 1.0 mm
2
Min. 1.5 mm
8 Technical data
Lower display:
4 mm
Green
7
Type AC 115 V:
Max. 3.6 W
Max. 4.2 W
2
2
, max. 1.5 mm
2
2
, max. 0.75 mm
Type DC 12 to 24 V:
Max. 1.7 W
Max. 2.3 W
2
29

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

701080701081

Table of Contents