4.2.7

Mirroring

To configure mirroring, select Advanced Application>Mirroring in the function
menu bar.
Parameter
Active
Monitor Port
Mirrored
Direction
Click Advanced Application > Mirroring.
1.
Enable mirroring; the monitoring port is port 8, the source port is port 7, and
2.
the mirror message is in both directions.
Click Apply.
3.
Web Smart Managed PoE Switches User Manual
【Parameter Description】
Description
Select to enable or disable Mirroring
Set up the monitoring port and forward the flow data of the
source port to the message analyzer to analyze the message
and then forward to the monitoring port
Check the box to configure the mirror source port
Configure the direction of the mirror message, choose:
Ingress, Egress, Both
【Configuration example】