Juniper Junos Pulse MAG2600 Hardware Manual page 62

Hide thumbs Also See for Junos Pulse MAG2600:
Table of Contents

Advertisement

®
Junos
Pulse Gateway Hardware Guide
46
The basic steps for installing the MAG-SM361 kit are:
Remove the face plate on the Junos Pulse Gateway corresponding to the slot where
1.
you want to install the MAG-SM361.
Service modules include an additional serial number. Remove this serial number and
2.
place it on the back panel of the Junos Pulse Gateway, directly behind the slot where
you are installing the MAG-SM361.
Service modules are paired with fan trays and hard drives. Hard drives have a serial
number sticker that matches the associated service module. Placing the service
module serial number sticker on the back panel of the Junos Pulse Gateway ensures
that you have the correct hard drive paired with the service module.
Install the MAG-SM361 in the open slot.
3.
Remove the blank fan tray covers on the back panel of the Junos Pulse Gateway
4.
directly behind the MAG-SM361 and install the fan trays in the slots.
NOTE:
It is important that you install the fan trays directly behind the
MAG-SM361 to ensure proper airflow across the service module.
Remove the blank hard drive covers on the back panel of the Junos Pulse Gateway
5.
directly behind the MAG-SM361 and install both hard drives.
Hard drives for the MAG-SM361 are slot dependent. The boot drive (labeled "bottom
slot drive") most be placed in the lower slot. The second drive (labelled "top slot
drive") must be placed in the upper slot.
NOTE:
Hard drives must be installed directly behind their corresponding
service module. They are labeled with the same serial number as their
paired service module to ensure they are installed in the correct slot. They
are also labeled with their slot location (top or bottom). Do not interchange
them.
If you do not install the hard drives in the correct slots, they will not be
recognized by the MAG-SM361 and you will receive a drive error when
powering up the Junos Pulse Gateway.
If the hard drives or MAG-SM361 service module fails, the entire kit must be replaced.
Since the hard drives are paired to the specific hardware ID, a failure of the hard drives
or the service module requires a full replacement rather than individual component
troubleshooting.
NOTE:
If you later move the MAG-SM361 service module to a different slot,
you must move its fan tray and hard drives to the new location as well.