Supplement; Technical Data - Vega VEGASWING 51 Operating Instructions Manual

Vibrating level switch for liquids
Table of Contents

Advertisement

9 Supplement

9
Supplement
9.1

Technical data

Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Tuning fork
Ʋ Process seal (in the scope of delivery) Ʋ Thread
Klingersil C-4400
FKM, EPDM
316L
Materials, non-wetted parts
Ʋ Housing
Ʋ Cable gland
Ʋ Sealing, cable gland
Ʋ Blind plug, cable gland
M12 x 1 plug connector
Ʋ Contact support
Ʋ Contacts
Ʋ Plug seal
Plug connector according to ISO 4400
Ʋ Contact, housing plug
Ʋ Lid screw
Ʋ Contact surface
Ʋ Plug seal
Weight
Process fittings
Ʋ Pipe thread, cylindrical (DIN 3852-A)
Ʋ Pipe thread, conical (ASME B1.20.1)
hygienic fittings
Ʋ Clamp (DIN 32676, ISO 2852)
Ʋ Slotted nut
Ʋ SMS
Ʋ Hygienic fitting
24
316L
Ʋ Hygienic connection with compression nut
Ʋ Process fittings
316L and plastic PEI
PA, stainless steel, brass
NBR
PA
PA
CuZn, nickel layer and 0.8 µm gold-plated
FKM
PA
StSt
Sn
Silicone
approx. 250 g (9 oz)
G½, G¾, G1, R1
½ NPT, ¾ NPT, 1 NPT
1", 1½", 2"
DN 25 PN 40, DN 40 PN 40, DN 50 PN 25
DN 38 PN 6
F 40 PN 25
VEGASWING 51 • Transistor (PNP)