L2 Parameters Setting - KUNTENG KT-LCD8HP User Manual

E-bike special meter
Table of Contents

Advertisement

ELECTRIC BICYCLE METER KT—LCD8H Product User Manual
L1 parameters are applicable to the automatic under-voltage controller. The
default of the factory is 0.
When L1=0, the automatic under-voltage controller can automatically select
the under-voltage value according to the battery voltage.
When L1=1, the under-voltage value of the automatic under-voltage controller
is forced to be 20V.
When L1 = 2, the under-voltage value of the automatic under-voltage
controller is forced to be 30V.
When L1 = 3, the under-voltage value of the automatic under-voltage
controller is forced to be 40V.
After finishing L1 parameter setting, press
setting interface
L2 parameter setting
Under parameter setting interface, move cursor to L2 and press
flashes
L2 parameter is suitable for the super high-speed motor controller. The default of
the factory is 0.
L2 parameter will be activated when the value of P1 parameter exceeds 255. L2
parameter should use in combination with P1.
When L2=0, P1 parameter is set as the calculated value.
When L2=1, P1 parameter is set as a half of the calculated value.
button (SW) to return to parameter
button shortly (SW), the value
- 36 -