P2 is wheel speed pulse signal setting, if wheel generated 1 pulse signal by a
revolution, P2 should be set as1. If wheel generated 6 pulse signals by a revolution, P2
should be set as 6. If users didn't configure the pulse signal system, and then P2 parameter
setting can be 0. The setting range of P2 should be between 0-6, hold
shortly or
button (DOWN) for selection.
After finishing P2 parameter setting, press
setting interface
Please Note:when P2 parameter is set to be 0, for the built-in clutch motor, there will
be the following defects, when the internal motor rotors stop or the internal rotor speed is
lower than the outer rotor speed, then the speed displayed on the meter is inaccurate!

P3 Power Assist Control Mode Setting

Under parameter setting interface, move cursor to P3 and press
flashes.
P3 is power assist control mode setting, when P3 parameter setting is1, power assist